Honeywell 4600GSF051C-0F00E User Manual - Page 56
Hands Free Time-Out, Reread Delay
View all Honeywell 4600GSF051C-0F00E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
Hands Free Time-Out The Scan Stand, and Presentation, and Streaming Presentation Modes are referred to as "hands free" modes. If the imager's trigger is pulled when using a hands free mode, the imager changes to manual trigger mode. You can set the time the imager should remain in manual trigger mode by setting the Hands Free Time-Out. Once the time-out value is reached, (if there have been no further trigger pulls) the imager reverts to the original hands free mode. Scan the Hands Free Time-Out barcode, then scan the time-out duration (from 0-300,000 milliseconds) from the inside back cover, and Save. Default = 5,000 ms. Hands Free Time-Out Reread Delay This sets the time period before the imager can read the same barcode a second time. Setting a reread delay protects against accidental rereads of the same barcode. Longer delays are effective in minimizing accidental rereads. Use shorter delays in applications where repetitive barcode scanning is required. Default = Medium. Reread Delay only works when in Presentation Mode or Streaming Presentation™ Mode (page 3-7). Short (500 ms) Long (1000 ms) * Medium (750 ms) Extra Long (2000 ms) 3 - 8 4600rp, 4600g/4600r, 4800i User's Guide