5. Finally, set up the ISBN check digit, which is a special position-weighted modulo 11 checksum. The imager automatically invokes the ISBN checksum for template rows that are: 1.) at least fourteen characters long, 2.) whose first four characters are the letters "ISBN," 3.) whose last character is a check character, and 4.) when the modulo 11 check character "0123456789X" is programmed. Please note that all these commands can be combined into a single serial programming command: OCRENA2,TMP"ISBNggggggggggggctCdddd hdddEtCdddd hddddE",GPG"0123456789-",GPH"P\",CHK"0123456789X". These commands can be encoded into the following Aztec Code symbol: OCR Template Codes Note: Reading more than three rows of OCR is not recommended. Contact the factory if you have an application that requires reading four or more rows of OCR. Enter OCR Template † Enter User-Defined Variable "g"† Enter User-Defined Variable "h"† † One or more two-digit numbers and Save are required after reading this programming symbol. Refer to the Programming Chart on the inside the back cover of this manual. 4600rp, 4600g/4600r, 4800i User's Guide 9 - 13