If the WC bit is set to one and errors occur in transfer or writing of the data, the device shall continue to transfer the amount of data requested and then provide ending status with BSY bit cleared to zero, the SE bit set to one, the ERR bit cleared to zero, and the type of error, ICRC, IDNF or ABRT reported in the error log. If the WC bit is set to one and the Command Completion Time Limit expires, the device shall stop execution of the command and provide ending status with the BSY bit cleared to zero, the SE bit set to one, the ERR bit cleared to zero, and report the fact that the Command Completion Time Limit expired by setting the CCTO bit in the error log to one. In all cases, the device shall attempt to transfer the amount of data requested within the Command Completion Time Limit even if some data transferred is in error. F (bit 5) HSE (bit 4) Stream ID (bit 0.2) Feature Previous F specifies that all data for the specified stream shall be flushed to the media before command complete is reported when set to one. HSE (Handle Stream Error) specifies that this command starts at the LBA of the last reported error for this stream, so the device may attempt to continue its corresponding error recovery sequence where it left earlier. Stream ID specifies the stream being written. The device shall operate according to the Stream ID set by the Write Stream command. The time allowed for the current command's completion is calculated as follows: Command Completion Time Limit = (content of the Feature register Previous) * (Identify Device words (99:98)) useconds If the value is zero, the device shall use the Default CCTL supplied with a previous Configure Stream command for this Stream ID. If the Default CCTL is zero, or no previous Configure Stream command was defined for this Stream ID, the device will ignore the CCTL. The time is measured from the write of the command register to the final INTRQ for command completion. Sector Count Current Sector Count Previous Sector Number Current Sector Number Previous Cylinder Low Current Cylinder Low Previous Cylinder High Current Cylinder High Previous The number of continuous sectors to be transferred low order, bits (7:0) The number of coninuous sectors to be transferred high order, bits (15:8). If zero is specified in the Sector Count register, then 65,536 sectors will be transferred. LBA (7:0) LBA (31:24) LBA (15:8) LBA (39:32) LBA (23:16) LBA (47:40) Input parameters from the device Sector Number (HOB=0) LBA (7:0) of the address of the first unrecoverable error. Deskstar T7K250 Hard Disk Drive Specification 240

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263

Deskstar T7K250 Hard Disk Drive Specification
240
If the WC bit is set to one and errors occur in transfer or writing of the data, the device
shall continue to transfer the amount of data requested and then provide ending status with
BSY bit cleared to zero, the SE bit set to one, the ERR bit cleared to zero, and the type of
error, ICRC, IDNF or ABRT reported in the error log.
If the WC bit is set to one and the Command Completion Time Limit expires, the device
shall stop execution of the command and provide ending status with the BSY bit cleared to
zero, the SE bit set to one, the ERR bit cleared to zero, and report the fact that the Com-
mand Completion Time Limit expired by setting the CCTO bit in the error log to one.
In all cases, the device shall attempt to transfer the amount of data requested within the
Command Completion Time Limit even if some data transferred is in error.
F (bit 5)
F specifies that all data for the specified stream shall be flushed to the media before com-
mand complete is reported when set to one.
HSE (bit 4)
HSE (Handle Stream Error) specifies that this command starts at the LBA of the last
reported error for this stream, so the device may attempt to continue its corresponding
error recovery sequence
where it left earlier.
Stream ID (bit 0.2)
Stream ID specifies the stream being written. The device shall operate according to the
Stream ID set by the Write Stream command.
Feature Previous
The time allowed for the current command's completion is calculated as follows:
Command Completion Time Limit = (content of the Feature register Previous) *
(Identify Device words (99:98)) useconds
If the value is zero, the device shall use the Default CCTL supplied with a previ-
ous Configure Stream command for this Stream ID.
If the Default CCTL
is zero,
or no previous Configure Stream command was defined for this Stream ID, the
device will ignore the CCTL.
The time is measured from the write of the com-
mand register to the final INTRQ for command completion.
Sector Count Current
The number of continuous sectors to be transferred low order, bits (7:0)
Sector Count Previous
The number of coninuous sectors to be transferred high order, bits
(15:8). If zero is specified in the Sector Count register, then
65,536 sectors will be transferred.
Sector Number Current
LBA (7:0)
Sector Number Previous
LBA (31:24)
Cylinder Low Current
LBA (15:8)
Cylinder Low Previous
LBA (39:32)
Cylinder High Current
LBA (23:16)
Cylinder High Previous
LBA (47:40)
Input parameters from the device
Sector Number (HOB=0)
LBA (7:0) of the address of the first unrecoverable error.