US 8 Installation instructions CA Special requirements for alcove or closet installation The minimum ventilation clearance between the washer and adjacent walls or other surfaces is: 1" (25 mm) minimum either side and front. 3" (75 mm) minimum rear. Consideration must be given to providing adequate clearance for installation and servicing. 60 Sq. In (388 Sq. cm) The minimum vertical space required from floor to overhead shelves, cabinets, ceilings, etc is 59" (1500 mm). Closet doors must be louvered or otherwise ventilated and have at least 60 square inches open area for a washer only, or if the closet contains both a washer and dryer, doors must contain at least 120 square inches of open area equally distributed. Louvered door Washer & Dryer 60 Sq. In (388 Sq. cm) Caution! Fig.11 Minimum ventilation clearance Do not install this appliance in a closet with a solid door. Mobile home installation Installation must conform to the STANDARD FOR MOBILE HOMES, ANSI A119.1 and NATIONAL MOBILE HOME CONSTRUCTION & SAFETY STANDARDS ACT OF 1974 (PL93-383). Grounding instructions This appliance must be grounded. In the event of malfunction or break down, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord that has an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. WARNING! Improper connection of an equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Specification subject to change without notice.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

8
US
CA
Installation instructions
Special requirements for alcove or closet installation
The minimum ventilation clearance between the washer and adjacent walls or other surfaces is:
1” (25 mm) minimum either side and front.
3” (75 mm) minimum rear.
Consideration must be given to providing adequate
clearance for installation and servicing.
The minimum vertical space required from floor
to overhead shelves, cabinets, ceilings, etc is
59” (1500 mm).
Closet doors must be louvered or otherwise
ventilated and have at least 60 square inches open
area for a washer only, or if the closet contains both
a washer and dryer, doors must contain at least
120 square inches of open area equally distributed.
Caution!
Do not install this appliance in a closet with a solid door.
Mobile home installation
Installation must conform to the STANDARD FOR MOBILE HOMES, ANSI A119.1 and NATIONAL
MOBILE HOME CONSTRUCTION & SAFETY STANDARDS ACT OF 1974 (PL93-383).
Grounding instructions
This appliance must be grounded. In the event of malfunction or break down, grounding will
reduce the risk of electric shock by providing a path of least resistance for electric current. This
appliance is equipped with a cord that has an equipment-grounding conductor and a grounding
plug. The plug must be plugged into an appropriate outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
WARNING!
Improper connection of an equipment-grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in doubt as to whether the appliance is
properly grounded.
Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper
outlet installed by a qualified electrician.
Specification subject to change without notice.
Louvered door
Washer & Dryer
60 Sq. In
(388 Sq. cm)
60 Sq. In
(388 Sq. cm)
Fig.11 Minimum ventilation clearance