Epson TM-T88V TM-T88V Technical Reference Guide - Page 56

For Serial Interface, DIP Switch Bank 1

Page 56 highlights

DIP switch bank 3 DIP switch bank 2 DIP switch bank 1 3 Set the DIP switches, using the tip of a tool, such as a small screwdriver. 4 Replace the DIP switch cover, and screw it in place. For Serial Interface When using the built-in USB interface, it is not necessary to change the DIP switch setting but their function changes. For the details, see "For Built-in USB Interface" on page 59. DIP Switch Bank 1 SW Function 1-1 Data reception error 1-2 Receive buffer capacity 1-3 Handshaking 1-4 Word length 1-5 Parity check 1-6 Parity selection 1-7 Transmission speed selections 1-8 ON OFF Ignored Prints "?" 45 bytes 4 KB XON/XOFF DTR/DSR 7 bits 8 bits Yes No Even Odd See the " Transmission Speed (DIP Switches 1-7/1-8)" table below. Default setting OFF OFF OFF OFF OFF OFF ON OFF For DIP switch 1-2 (Receive buffer capacity), see also DIP switch 2-5 (Sets the release condition of the receive buffer BUSY state.) 56

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

56
3
Set the DIP switches, using the tip of a tool, such as a small screwdriver.
4
Replace the DIP switch cover, and screw it in place.
For Serial Interface
When using the built-in USB interface, it is not necessary to change the DIP switch setting but
their function changes. For the details, see
"For Built-in USB Interface" on page 59
.
DIP Switch Bank 1
SW
Function
ON
OFF
Default
setting
1-1
Data reception error
Ignored
Prints “?”
OFF
1-2
Receive buffer capacity
45 bytes
4 KB
OFF
1-3
Handshaking
XON/XOFF
DTR/DSR
OFF
1-4
Word length
7 bits
8 bits
OFF
1-5
Parity check
Yes
No
OFF
1-6
Parity selection
Even
Odd
OFF
1-7
Transmission speed selections
See the
“ Transmission Speed (DIP Switches
1-7/1-8)”
table below.
ON
1-8
OFF
For DIP switch 1-2 (Receive buffer capacity), see also DIP switch 2-5 (Sets the release
condition of the receive buffer BUSY state.)
DIP switch bank 1
DIP switch bank 2
DIP switch bank 3