Dell PowerEdge M1000e Fabric OS Release Notes - Page 56

Defect ID, Technical Severity, Summary, Symptom, Feature, Function, Probability, Found in Release

Page 56 highlights

Close with Code Change in Fabric OS v6.4.0b Defect ID: DEFECT000302002 Technical Severity: Medium Summary: Unable to disable default zone from Mi10k in interop fabric(FOS and Mi10k) in IM2 mode Symptom: After a zone merge failure between Mi10k and FOS switches, disable Default zone from Mi10k, throws error as "Error: Zone Activation failed due to error in pushing the data to the rest of the fabric", need a switch reboot to recover. Feature: FC Services Function: Zoning Probability: Low Found in Release: FOS6.4.0 Defect ID: DEFECT000302325 Technical Severity: Medium Summary: The Brocade 7800 does not support the Path Down function in IM2 mode. Symptom: Fabric becomes unstable and segments when one leg of a TI Zone with Failover Disabled is disrupted. Feature: FC Services Function: FSPF Probability: High Found in Release: FOS6.3.0 Defect ID: DEFECT000303264 Technical Severity: Medium Summary: Tape pipelining I/O errors observed when forcing a drop of last data frame Symptom: IO errors when forcing drop of last data frame with tape pipelining enabled. Feature: FCIP Function: Emulation Probability: Low Found in Release: FOS6.4.0 Fabric OS v6.4.1 Release Notes v1.0 Page 56 of 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

Close with Code Change in Fabric OS v6.4.0b
Fabric OS v6.4.1 Release Notes v1.0
Page 56 of 62
Defect ID:
DEFECT000302002
Technical Severity:
Medium
Summary:
Unable to disable default zone from Mi10k in interop fabric(FOS and Mi10k) in IM2 mode
Symptom:
After a zone merge failure between Mi10k and FOS switches, disable Default zone from
Mi10k, throws error as "Error: Zone Activation failed due to error in pushing the data to the
rest of the fabric", need a switch reboot to recover.
Feature:
FC Services
Function:
Zoning
Probability:
Low
Found in Release:
FOS6.4.0
Defect ID:
DEFECT000302325
Technical Severity:
Medium
Summary:
The Brocade 7800 does not support the Path Down function in IM2 mode.
Symptom:
Fabric becomes unstable and segments when one leg of a TI Zone with Failover Disabled is
disrupted.
Feature:
FC Services
Function:
FSPF
Probability:
High
Found in Release:
FOS6.3.0
Defect ID:
DEFECT000303264
Technical Severity:
Medium
Summary:
Tape pipelining I/O errors observed when forcing a drop of last data frame
Symptom:
IO errors when forcing drop of last data frame with tape pipelining enabled.
Feature:
FCIP
Function:
Emulation
Probability:
Low
Found in Release:
FOS6.4.0