Verify Scan, Double-Feed Detection Function, Setting the Count.
![]() |
View all Canon imageFORMULA DR-X10C II manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
Verify Scan The scanner compares the document page count obtained from the Count-Only mode (or entered manually) with the actual count of document pages scanned, and an error message is displayed if the counts do not match. 1 Setting the Count. Hint If the specified count is exceeded while scanning, or if the scanned count does not reach the specified count when scanning is finished, an error is displayed. The specified count is exceeded while scanning Hint The document page count can be specified by using the count obtained from the Count-Only mode or by pressing the [ ] and [ ] keys to enter a number. 2 Select Verify Count in the ISIS/TWAIN driver settings. 3 Press the Start Key to start scanning. "Verifying..." is displayed. Scanning finishes without reaching the specified count Double-Feed Detection Function The scanner can detect double feeds. Two detection methods are used: comparison of document lengths, and ultrasonic detection of spacing between documents, which is set in the ISIS/TWAIN driver. 66