Campbell Scientific CR200 Operation Manual - Page 32
Programming the CR200X and Collecting Data
View all Campbell Scientific CR200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Section 2. Quickstart Tutorial 2.2.3.2 Programming the CR200(X) and Collecting Data 2.2.3.2.1 Procedure (PC200W Step 1) 1. From the PC200W Clock/Program tab, click on the Connect button to establish communications with the CR200(X). When communications have been established, the text on the button will change to Disconnect. Figure 18: PC200W Connect Button 2.2.3.2.2 Procedure (PC200W Steps 2-4) 1. Click the Set Clock button to synchronize the datalogger's clock with the computer's clock. 2. Click on the Send Program button. A window will appear warning that data on the datalogger will be erased. Answer "yes" to the prompt. Another window will open. Browse to the C:\CampbellSci\SCWin folder, select the QuickStart.CR2 file, and then click the Open button. A status bar will appear while the program is sent to the CR200(X) followed by a confirmation that the transfer was successful. Click OK to close this window. 3. After sending a program to the CR200(X), a good practice is to monitor the measurements to ensure they are reasonable. Select the Monitor Data tab. The window now displays data found in the Public Table coming from the CR200(X). To view the OneMin table, select an empty cell in the display area, and then click on the Add button. 18