Campbell Scientific CR200 Operation Manual - Page 132

SDI-12 Power Considerations

Page 132 highlights

Section 11. Programming Resource Library SDIRecorder () Instruction SDICommand Entry Mv! Actions Internal to CR200(X) and Sensor CR200(X): Issues aMv! command Sensor: Responds with atttnn CR200(X): Waits until ttt1 seconds. Issues aDv! command(s) Sensor: Responds with data. Cv! CR200(X): Issues aCv! command Sensor: Responds with atttnn CR200(X): If ttt=0 then issues aDv! command(s) Sensor: Responds with data. CR200(X): else, if ttt>0 then moves to next CRBASIC program instruction. CR200(X): At next time SDIRecorder() is executed, if elapsed time < ttt, moves to next CRBASIC instruction,. CR200(X): else, issues aDv! command(s) Sensor: Responds with data. CR200(X): Issues aCv! command (to request data for next scan). Cv (note: no ! termination) CR200(X): Tests to see if ttt expired. If ttt not expired, loads "1e9" into first variable then moves to next CRBASIC instruction. If ttt expired, issues aDv! command(s). Sensor: Responds to aDv! command(s) with data, if any. If no data, loads NAN into variable. CR200(X): moves to next CRBASIC instruction (does not re-issue aCv! command). 1Note that ttt is local only to the SDIRecorder() instruction. 11.4.3 SDI-12 Power Considerations When a command is sent by the datalogger to an SDI-12 probe, all probes on the same SDI-12 port will wake up. Only the probe addressed by the datalogger 118

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210

Section 11.
Programming Resource Library
SDIRecorder () Instruction
SDICommand
Entry
Actions Internal to CR200(X) and
Sensor
Mv!
CR200(X)
: Issues
aMv!
command
Sensor
: Responds with
atttnn
CR200(X)
: Waits until
ttt
1
seconds.
Issues
aDv!
command(s)
Sensor
: Responds with data.
Cv!
CR200(X)
: Issues aCv! command
Sensor
: Responds with atttnn
CR200(X)
: If
ttt
=0 then issues
aDv!
command(s)
Sensor
: Responds with data.
CR200(X)
: else, if
ttt
>0 then moves to
next CRBASIC program instruction.
CR200(X)
: At next time SDIRecorder()
is executed, if elapsed time <
ttt
, moves
to next CRBASIC instruction,.
CR200(X)
: else, issues
aDv!
command(s)
Sensor
: Responds with data.
CR200(X)
: Issues
aCv!
command (to
request data for next scan).
Cv
(note: no ! termination)
CR200(X)
: Tests to see if
ttt
expired.
If
ttt
not expired, loads "1e9" into first
variable then moves to next CRBASIC
instruction.
If
ttt
expired, issues
aDv!
command(s).
Sensor
: Responds to
aDv!
command(s)
with data, if any.
If no data, loads NAN
into variable.
CR200(X)
: moves to next CRBASIC
instruction (does not re-issue
aCv!
command).
1
Note that
ttt
is local only to the SDIRecorder() instruction.
11.4.3
SDI-12 Power Considerations
When a command is sent by the datalogger to an SDI-12 probe, all probes on
the same SDI-12 port will wake up. Only the probe addressed by the datalogger
118