Adaptec 5405Z User Guide - Page 22
arcconf setncq, arcconf setperform, Performance Mode is 1 DYNAMIC/Default or 2 OLTP/Database.
UPC - 760884156179
View all Adaptec 5405Z manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Chapter 2: Using the Command Line Utility ● 22 Example ARCCONF SETNAME 1 LOGICALDRIVE 1 BACKUP_A arcconf setncq Changes the controller's Native Command Queuing (NCQ) setting to enabled or disabled. This setting affects the SATA disk drives on the controller. It takes effect when the SATA drives are restarted. Syntax ARCCONF SETNCQ ENABLE|DISABLE Parameters Controller# is the controller number. Example ARCCONF SETNCQ 1 ENABLE arcconf setperform Changes controller settings based on the application. Syntax ARCCONF SETPERFORM Parameters Controller# is the controller number. Performance Mode is 1 (DYNAMIC/Default) or 2 (OLTP/Database). Example ARCCONF SETPERFORM 1 2 arcconf setpower Changes power management settings for disk drives on a controller or logical drive. Syntax ARCCONF SETPOWER Stayawake DISABLE| ARCCONF SETPOWER Spinup ARCCONF SETPOWER LD DISABLE|[SLOWDOWN ] [POWEROFF ] [VERIFY ] Parameters Controller# is the controller number. Stayawake sets the stayawake period for the disk drives on the controller. During the stayawake period, the disk drives always operate at their peak spin rate. Disable is a keyword that disables the stayawake period for the disk drives on a controller. starttime specifies the beginning of the stayawake period, in the form HHMM (24-hour format). endtime specifies the end of the stayawake period, in the form HHMM (24-hour format). Spinup sets the spin-up limits for the controller-the maximum number of drives that the controller may spin up at one time.