Viking VQGI5421 Installation / Use and Care Instructions - Page 9
Model-specific Btu Outputs & Max. Runs For Appliances, Specifications & Installation
View all Viking VQGI5421 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
SPECIFICATIONS & INSTALLATION COUNTER TOP NOTCH DETAIL Only required if island counter top overhangs the face of the island A 5" (12.7 cm) 4.5" (11.4 cm) C 3" (7.6 cm) B MODEL-SPECIFIC BTU OUTPUTS & MAX. RUNS FOR APPLIANCES MODEL-SPECIFIC BTU OUTPUTS MODEL H BURNER (Btu) ROTISSERIE (Btu) PROSEAR™ (Btu) TOTAL INPUT VQGI5301/VQGFS5301 (N/L)SS 1 @ 25,000 1 @ 14,000 1 @ 21,000 60,000 Btu/Hr VQGI5361/ VQGFS5361 (N/L)SS 2 @ 25,000 1 @ 14,000 1 @ 21,000 85,000 Btu/Hr VQGI5421/ VQGFS5421 (N/L)SS 2 @ 25,000 1 @ 16,000 1 @ 21,000 87,000 Btu/Hr VQGI5541/ VQGFS5541 (N/L)SS 3 @ 25,000 2 @ 14,000 1 @ 21,000 124,000 Btu/Hr MAXIMUM RUNS FOR ALL APPLIANCES ON SUPPLY LINE Run Length 3/4" Pipe (in feet) Max BTU for all Appliances on line 10 360,000 20 245,000 30 198,000 40 169,000 50 150,000 60 135,000 70 123,000 80 115,000 | INSTALLATION / USE & CARE 9