TASCAM SS-R250N 32C/TELNET Protocol Specifications Ver1.15 - Page 27

Keyboard Type Sense, Power Contorl, Error Sense, Caution Snese, Vender Command, Vender Command

Page 27 highlights

RS-232C/TELNET Protocol Specifications Ver. 1.15 SS-CDR250N/SS-R250N ・KEYBOARD TYPE SENSE KEYBOARD TYPE SENSE requests the controlled device to return the current keyboard type setting of the controlled device. Command Data Return 5F None KEYBOARD TYPE RETURN [DF] ・POWER CONTORL POWER CONTROL turns ON / OFF (standby) the power of the controlled device. When turning on from OFF, the REMOTE POWER CONTROL setting of the controlled device must be ON. Command 75 Data None Return POWER CONTROL RETURN [F5] Data 1 0 1 8 Data 2 0 1 0 Description Power On Power Off Reset Remarks Power on from the standby state. The controlled device enters the standby state. The controlled device restarts. If the controlled device does not stop, it sends ILLEGAL [F2]. ・ERROR SENSE ERROR SENSE requests the controlled device to return information about an error that occurred on the controlled device. Be sure to determine the error by using this command if the ERROR SENSE REQUEST command [F0] is issued from the controlled device. Command: Data: Return: 78 None ERROR SENSE RETURN [F8] ・CAUTION SNESE CAUTION SENSE requests the controlled device to return information about a caution that is shown on the controlled device. Be sure to check the caution by using this command if the CAUTION SENSE REQUEST command [F1] is issued from the controlled device. Command: Data: Return: 79 None CAUTION SENSE RETURN [F9] ・VENDER COMMAND This command controls a function unique to this unit. For details, see "Vender command details" on page 39. Command: Return: 7F VENDER COMMAND RETURN [FF] - 27 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59

RS-232C/TELNET Protocol Specifications Ver. 1.15
SS-CDR250N/SS-R250N
- 27 -
KEYBOARD TYPE SENSE
KEYBOARD TYPE SENSE requests the controlled device to return the current keyboard type setting of the
controlled device.
Command
5F
Data
None
Return
KEYBOARD TYPE RETURN [DF]
POWER CONTORL
POWER CONTROL turns ON / OFF (standby) the power of the controlled device.
When turning on from OFF, the REMOTE POWER CONTROL setting of the controlled device must be ON.
Command
75
Data
None
Return
POWER CONTROL RETURN [F5]
Data 1
Data 2
Description
Remarks
0
0
Power On
Power on from the standby state.
1
1
Power Off
The controlled device enters the standby state.
8
0
Reset
The controlled device restarts.
If the controlled device does not stop, i
t sends ILLEGAL [F2].
ERROR SENSE
ERROR SENSE requests the controlled device to return information about an error that occurred on the
controlled device. Be sure to determine the error by using this command if the ERROR SENSE REQUEST
command [F0] is issued from the controlled device.
Command:
78
Data:
None
Return:
ERROR SENSE RETURN [F8]
CAUTION SNESE
CAUTION SENSE requests the controlled device to return information about a caution that is shown on the
controlled device. Be sure to check the caution by using this command if the CAUTION SENSE REQUEST
command [F1] is issued from the controlled device.
Command:
79
Data:
None
Return:
CAUTION SENSE RETURN [F9]
VENDER COMMAND
This command controls a function unique to this unit. For details, see
"Vender command details"
on page 39.
Command:
7F
Return: