TASCAM SS-R250N 32C/TELNET Protocol Specifications Ver1.15 - Page 22

Auto Ready Select, Repeat Select, Sync Rec Select

Page 22 highlights

RS-232C/TELNET Protocol Specifications Ver. 1.15 SS-CDR250N/SS-R250N ・AUTO READY SELECT AUTO READY SELECT turns the auto ready mode of the controlled device on or off. Only when this command is sent with request data [FF], the controlled device sends the AUTO READY SELECT RETURN command [B6]. Command 36 Data 2 bytes Return AUTO READY SELECT RETURN [B6] Data 1 Data 2 Description Remarks 0 0 Auto-ready OFF 0 1 Auto-ready ON F F Sense Requests the controlled device to return the current auto-ready mode setting ·If the controlled device receives data other than the above data, it sends ILLEGAL (F2). ・REPEAT SELECT REPEAT SELECT turns the repeat mode of the controlled device on or off. Only when this command is sent with request data [FF], the controlled device sends the REPEAT SELECT RETURN command [B7]. Command 37 Data 2 bytes Return REPEAT SELECT RETURN [B7] Data 1 Data 2 Description Remarks 0 0 Repeat OFF 0 1 Repeat ON F F Sense Requests the controlled device to return the current repeat mode setting ·If the controlled device receives data other than the above data, it sends ILLEGAL (F2). ・SYNC REC SELECT SYNC REC SELECT turns the sync rec mode of the controlled device on or off. Only when this command is sent with request data [FF], the controlled device sends the SYNC REC SELECT RETURN command [B8]. The sync rec level can be set using the SYNC REC LEVEL PRESET command [28]. Command 38 Data 2 bytes Return SYNC REC SELECT RETURN [B8] Data 1 Data 2 Description Remarks 0 0 sync rec OFF 0 1 Sync rec ON F F Sense Requests the controlled device to return the current sync rec mode setting ·If the controlled device receives data other than the above data, it sends ILLEGAL (F2). - 22 -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59

RS-232C/TELNET Protocol Specifications Ver. 1.15
SS-CDR250N/SS-R250N
- 22 -
AUTO READY SELECT
AUTO READY SELECT turns the auto ready mode of the controlled device on or off.
Only when this command is sent with request data [FF], the controlled device sends the AUTO READY
SELECT RETURN command [B6].
Command
36
Data
2 bytes
Return
AUTO READY SELECT RETURN [B6]
Data 1
Data 2
Description
Remarks
0
0
Auto-ready OFF
0
1
Auto-ready ON
F
F
Sense
Requests the controlled device to return the current
auto-ready mode setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
REPEAT SELECT
REPEAT SELECT turns the repeat mode of the controlled device on or off.
Only when this command is sent with request data [FF], the controlled device sends the REPEAT SELECT
RETURN command [B7].
Command
37
Data
2 bytes
Return
REPEAT SELECT RETURN [B7]
Data 1
Data 2
Description
Remarks
0
0
Repeat OFF
0
1
Repeat ON
F
F
Sense
Requests the controlled device to return the
current repeat mode setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).
SYNC REC SELECT
SYNC REC SELECT turns the sync rec mode of the controlled device on or off.
Only when this command is sent with request data [FF], the controlled device sends the SYNC REC SELECT
RETURN command [B8].
The sync rec level can be set using the SYNC REC LEVEL PRESET command [28].
Command
38
Data
2 bytes
Return
SYNC REC SELECT RETURN [B8]
Data 1
Data 2
Description
Remarks
0
0
sync rec OFF
0
1
Sync rec ON
F
F
Sense
Requests the controlled device to return the
current sync rec mode setting
·If the controlled device receives data other than the above data, it sends ILLEGAL (F2).