Sony STRDG1100 Operating Instructions - Page 106
To operate on the receiver, To confirm/save auto calibration, when GUI function is turned off
![]() |
UPC - 027242710931
View all Sony STRDG1100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
Performing auto calibration For details on the auto calibration, see "9: Calibrating the appropriate speaker settings automatically (Auto Calibration)" (page 42). Refer to "Before you perform the auto calibration" (page 42) before performing the auto calibration. To operate on the receiver 1 Press SHIFT, then press MENU to set the GUI display mode to off. The menu appears on the TV screen when "GUI MODE" appears on the display. 2 Press AMP. Receiver operation is enabled. 3 Press MENU. "Auto Calibration" is displayed. 4 Press . 5 Press V/v repeatedly to select "AUTO CAL START?," then press to start the measurement. Measurement starts in five seconds. A count down is displayed. Note While the time is counting down, stand away from the measurement area to avoid measurement error. 6 Measurement starts. The measurement process will take approximately 30 seconds. Wait until the measurement process completes. To cancel auto calibration, change the volume, activate the MUTING function, switch functions, change the setting of the SPEAKERS switch of the receiver, or connect headphones. Note You cannot measure the speaker height of the surround speakers and the surround back speakers. Set this value from "SP POSI." settings in the Speaker settings menu. Tips • Operations other than turning the receiver on or off are deactivated during auto calibration. • When special speakers, such as dipole speakers are used, the measurements may not be performed correctly or auto calibration cannot be performed. To confirm/save auto calibration when GUI function is turned off 1 Confirm the measurement result. When the measurement ends, a beep sounds and the measurement result appears on the display. Measurement Display Explanation result When the measurement process completes properly When the measurement process fails COMPLETE Proceed to step 2. ERROR CODE 3x See "Message list after auto calibration measurement" (page 47). 2 Press V/v repeatedly to select the item, then press . The measurement results are saved. Item Explanation RETRY Re-performs the auto calibration. SAVE EXIT Saves the measurement results and exits the setting process. WRN CHECK Displays a warning concerning the measurement results. See "When you select "WRN CHECK"" (page 47). PHASE INFO Displays the phase of each speaker (in phase/out of phase). See "When you select "PHASE INFO"". DIST.INFO Displays the measurement result for speaker distance. LEVEL INFO Displays the measurement result for speaker level. 106GB
![](/manual_guide/products/sony-strdg1100-operating-instructions-908b153/106.png)