Sharp PN-Y325 Operation Manual - Page 39
Command-based control, Connect the PC to the monitor., Send commands to control the monitor.
![]() |
View all Sharp PN-Y325 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Command-based control You can control the monitor using RS-232C commands (see page 36) via terminal software and other appropriate applications. Read the manual for the terminal software for detailed instructions. (1) Connect the PC to the monitor. 1. Specify the IP address and data port number (fixed at "10008"), and connect the PC to the monitor. When connection has been established successfully, [ Login:] is returned as response. 2. Enter the user name and password. (The default settings are blank.) (2) Send commands to control the monitor. • The commands used are the same as those for RS232C. Refer to the communication procedure (see page 32) for operation. • Usable commands are provided in the RS-232C command table (see page 36). (3) Disconnect the connection with the monitor and quit the function. 1. Send [BYE ]. When the transmission is successful, [goodbye] is returned and the connection is disconnected. TIPS • The connection is automatically disconnected if there is no communication for about 5 minutes. Controlling the Monitor with a PC (LAN) 39 E
![](/manual_guide/products/sharp-pny325-operation-manual-176eece/39.png)