Sharp PN-V550A PN-V550A Operation Manual - Page 57

[Advanced operation] Command‑based control, Connect the PC to the monitor.

Page 57 highlights

[Advanced operation] Command‑based control You can control the monitor using RS-232C commands (see page 42) via terminal software and other appropriate applications. In order to use this function, enable a connection to the monitor through Internet Explorer. Read the manual for the terminal software for detailed instructions. (1) Connect the PC to the monitor. 1. Specify the IP address and data port number and connect the PC to the monitor. When connection has been established successfully, [ Login:] is returned as response. 2. Send the user name set in the SECURITY settings (see page 53). • Send [User name If the user name is not set, send [ ]. • When the transmission is successful, [ Password:] is returned as response. 3. Send the password set in the SECURITY settings (see page 53). • Send [Password If the password is not set, send [ ]. • When the transmission is successful, [OK ] is returned as response. (2) Send commands to control the monitor. • The commands used are the same as those for RS232C. Refer to the communication procedure (see page 38) for operation. • Usable commands are provided in the RS-232C command table (see page 42). (3) Disconnect the connection with the monitor and quit the function. 1. Send [BYE ]. When the transmission is successful, [goodbye] is returned and the connection is disconnected. TIPS • Connection is automatically disconnected when the time specified in AUTO LOGOUT TIME elapses over a no‑communication period. Controlling the Monitor with a PC (LAN) 57 E

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66

57
E
Controlling the Monitor with a PC (LAN)
[Advanced operation]
Command-based control
You can control the monitor using RS-232C commands
(see page 42) via terminal software and other appropriate
applications.
In order to use this function, enable a connection to the
monitor through Internet Explorer.
Read the manual for the terminal software for detailed
instructions.
(1) Connect the PC to the monitor.
1. Specify the IP address and data port number and
connect the PC to the monitor.
When connection has been established successfully,
[
Login:] is returned as response.
2. Send the user name set in the SECURITY settings (see
page 53).
• Send [User name] + [
].
If the user name is not set, send [
].
When the transmission is successful, [
Password:]
is returned as response.
3. Send the password set in the SECURITY settings (see
page 53).
• Send [Password] + [
].
If the password is not set, send [
].
When the transmission is successful, [OK
] is
returned as response.
(2) Send commands to control the monitor.
The commands used are the same as those for RS-
232C. Refer to the communication procedure (see
page 38) for operation.
Usable commands are provided in the RS-232C
command table (see page 42).
(3) Disconnect the connection with the monitor and
quit the function.
1. Send [BYE
].
When the transmission is successful, [goodbye] is
returned and the connection is disconnected.
TIPS
Connection is automatically disconnected when the
time specified in AUTO LOGOUT TIME elapses over a
no-communication period.