Sanyo PLC-XW250 RS232 Expand - Page 54
CR_LAMPMSTS Command, CR_PROJH Command, CR_HMLAMP Command, CR_LAMPLIFECONTRL Command
UPC - 086483074776
View all Sanyo PLC-XW250 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 54 highlights
PLC-XW200/250 Expand Serial Command Functional Specifications 9.9.5 CR_LAMPMSTS Command Command "CR_LAMPSTS"[CR] Details Get Lighting status of lamp Acceptable "000_%1"[CR] "n**** " A number of * should be among 1-4. First character shows how many lamps are incorporated in projector. (1,2 or 4 ) Response %1 Unacceptable Secound character shows follwing status in order of lamp number. "I" Lamp is ON "O" Lamp is OFF "X" Lamp failure e.g. "1I" 1 Iamp model and Lamp is ON "2IO 2 lamps model and No.1 Lamp is ON and No.2Lamp is OFF "4IOXI" 4 lamps model and No.1,No.4 lamps are ON. No.2 lamp is OFF and No.3 model is failed. "Error Code"[CR] 9.9.6 CR_PROJH Command Command "CR_PROJH"[CR] Details Get total running time of Projector by hour (h) Acceptable "000_%1"[CR] Response %1 "0000000"~"0099999" Unacceptable "Error Code"[CR] 9.9.7 CR_HMLAMP Command Command "CR_HMLAMP"[CR] Details Get lamp number. Acceptable "000_%1"[CR] Response %1 "001" Unacceptable "Error Code" [CR] 9.9.8 CR_LAMPLIFECONTRL Command Command "CR_LAMPLIFECONTRL"[CR] Details Get setting status of Lamp life control. Acceptable "000_%1"[CR] Response %1 "MODE1 Mode1 is selected "MODE2 Mode2 is selected Unacceptable "Error Code" [CR] 53 / 64