Sanyo PLC-XW250 RS232 Expand - Page 15
Functional Execution Command, Format, Transfer Example, Operation Requirements
UPC - 086483074776
View all Sanyo PLC-XW250 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
PLC-XW200/250 Expand Serial Command Functional Specifications 8. Functional Execution Command 8.1 Format 1. PC issues commands in format as below: Pattern1 : "CF_COMMAND" [CR] Pattern2 : "CF_COMMAND_"%1 [CR] CF_ : Header COMMAND : Character line %1 : Parameter (Character line) _ : Space (To separate COMMAND and Parameter) 2. The projector decodes the received command and when it is ready to receive the next command, it returns the response. "000" [CR] : (0x06, 0x0D) When receiving Functional Execution Command "nnn" [CR] : Except "000" , when it is unable to execute command by any specific reason. See Error Code Table for details 3. When the received data cannot be decoded, the projector returns "?" [CR] 8.2 Transfer Example When setting projector's total dots to 1344 by Expand Serial Command PC → PJ: "CF_TDOTS_1344" [CR] PC ← PJ: "000"[CR Acceptable 8.3 Operation Requirements 1) Functional Execution Command is limited when the projector status is as below. However, Status Read Command is effective even under these conditions. Projector Status Available Functional Execution Command Standby Mode Countdown in process Cooling down in process Cooling down in process due to Abnormal Temperature Abnormal Temperature Power Failure (For 60 seconds after Power Failure occurred) Power Save / Cooling down in process Power Save in process C00: POWER ON C00: POWER ON (Terminates Countdown) C01: POWER OFF C02: POWER OFF (Terminates Countdown) N/A N/A N/A N/A N/A C00: POWER ON C01: POWER OFF Note:) When the projector receives the other command in this above status, it returns error code to show the status. When the projector receives the following functional execution commands, OSD menu is closed except for pop-up menu 2) When Eco mode is selected in Standby mode of Setting menu and projector is in Standby, Functional Execution Commands are invalid. 14 / 64