Sanyo PLC-WTC500L RS232C Basic - Page 20

Status Read Command, 1 Format, 2 Transfer Example, 3 Operation Requirements, 4 Status Read Command

Page 20 highlights

PLC-WTC500L Basic Serial Command Functional Specifications 7 Status Read Command 7.1 Format PC issues a command in the following format. "CR" Command [CR] Command: one character (See Status Read Command Table) When projector receives an appropriate command, it returns the required data in string. Required Data [CR] Required Data: string (See Status Read Command Table) When the received data cannot be decoded, the projector returns "?" [CR] is returned. 7.2 Transfer Example Getting Input mode information of projector by basic commands. PC Projector Projector PC Command (issue current input mode command) "C" "R" "1" CR "1" CR Response (A few ms 5 s) (Indicating Computer 1 is selected) 7.3 Operation Requirements When Standby mode of Setting menu is set to Eco and Projector status is Standby mode, Functional execution commands become invalid 7.4 Status Read Command Command "CR0" [CR] Detail Get the projector's operating status Acceptable "%1" [CR] "00" = Power ON "80" = Standby "40" = Countdown in process "20" = Cooling Down in process "10" = Power Failure "28" = Cooling Down in process due to Abnormal Temperature "88" = Standby after Cooling Down due to Abnormal Temperature Response %1 "24" = Power-Save Cooling Down in process "04" = Power Save "21" = Cooling Down in process after OFF due to Lamp Failure "81" = Standby after Cooling Down due to Lamp Failure "2C" = Cooling Down in process after Power Off due to Shutter management "8C" = Standby after Cooling Down due to Shutter management Unacceptable "?" [CR] 20/25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25

PLC-WTC500L
Basic Serial Command Functional Specifications
20/25
7
Status Read Command
7.1 Format
PC issues a command in the following format.
“CR” Command [CR]
Command: one character (See Status Read Command Table)
When projector receives an appropriate command, it returns the required data in string.
Required Data [CR]
Required Data: string (See Status Read Command Table)
When the received data cannot be decoded, the projector returns
“?”
[CR]
is returned.
7.2 Transfer Example
Getting Input mode information of projector by basic commands.
Command (issue current input mode command)
PC
Projector
“C”
“R”
“1”
CR
Projector
PC
“1”
CR
�����
Response
(A few
ms
5 s
)
(Indicating Computer 1
is selected)
7.3 Operation Requirements
When Standby mode of Setting menu is set to Eco and Projector status is Standby mode, Functional
execution commands become invalid
7.4 Status Read Command
Command
“CR0” [CR]
Detail
Get the projector’s operating status
Response
Acceptable
“%1” [CR]
%1
”00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to Abnormal Temperature
“88” = Standby after Cooling Down due to Abnormal Temperature
“24” = Power-Save Cooling Down in process
“04” = Power Save
“21” = Cooling Down in process after OFF due to Lamp Failure
“81” = Standby after Cooling Down due to Lamp Failure
“2C” = Cooling Down in process after Power Off due to
Shutter management
“8C” = Standby after Cooling Down due to
Shutter management
Unacceptable
“?” [CR]