Pyle PLTM40 User Manual - Page 14
Inmunun
View all Pyle PLTM40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
4.7.1 Connect the black test lead to the COM jack and the red test lead to the mA jack for a maximum of 200mA current, For a maximum of 20A, move the red lead to the 20A jack. 4.7.2 Set the transform switch at the desired mA or A range position. 4.7.3 Connect test leads in series with the load under measurement. 4.7.4 You can get reading from LCD. The polarity of red test lead will be indicated. NOTE: • When only the figure "1" is displayed, it indicates overrange situation and the higher range has to be selected. • When the value scale to be measured is unknown beforehand, set the range selector at the highest position. • " 4k " means the socket of mA maximum current is 200mA, Bver current wiu destory the fuse. 20 A's maximum current is 20A, no fuse protection. 4.8 MEASURING AC CURRENT A WARNING Shut down the power of the tested circuit, then connect the meter with the circuit for measurement. Inmunun i'mnnu O 868 A 08 11