How To Install The Indoor Unit
![]() |
View all Panasonic WU-144MF1U9E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
3. HOW TO INSTALL THE INDOOR UNIT ■ 4-Way Cassette Type (U1 Type) 3-1. Preparation for Suspending This unit uses a drain pump. Use a level gauge to check that the unit is level. Note: For DC Fan Tap Change Procedure for 4-Way Cassette, see page 16. Hole-in-anchor Hole-in-plug Concrete Inser t B (suspension bolt pitch) D (ceiling opening dimension) 3-2. Suspending the Indoor Unit (1) Fix the suspension bolts securely in the ceiling using the method shown in the diagrams (Figs. 3-1 and 3-2), by attaching them to the ceiling support structure, or by any other method that ensures that the unit will be securely and safely suspended. (2) Follow Fig. 3-2 and Table 3-1 to make the holes in the ceiling. Table 3-1 Type Length 12, 18, 24, 36 A 31-1/32 (788) Unit: in. (mm) B 28-15/32 (723) C 34-27/32 (885) D 34-27/32 (885) (3) Determine the pitch of the suspension bolts using the supplied fullscale installation diagram. The diagram and table (Fig. 3-3 and Table 3-2) show the relationship between the positions of the suspension fitting, unit, and panel. Table 3-2 Type Length 12, 18, 24 36 A 4-29/64 (113) 4-29/64 (113) B 6-13/16 (173) 6-13/16 (173) C 10-5/64 (256) 12-9/16 (319) Unit: in. (mm) D 8-17/64 (210) 8-17/64 (210) E 3-15/32 (88) 3-15/32 (88) Drain outlet(other side) (VP25) Refrigerant tubing joint(liquid side) Suspension bolt (M10 or 3/8") (field supply) Fig. 3-1 A (suspension bolt pitch) C (ceiling opening dimension) Fig. 3-2 Refrigerant tubing joint(gas side) Suspension lug A B C 1-3/8 (35) D E Fig. 3-3 Over 19/32 (15) 3-3. Placing the Unit Inside the Ceiling (1) When placing the unit inside the ceiling, determine the pitch of the suspension bolts using the supplied fullscale installation diagram. (Fig. 3-4) Tubing and wiring must be laid inside the ceiling when suspending the unit. If the ceiling is already constructed, lay the tubing and wiring into position for connection to the unit before placing the unit inside the ceiling. Supplied bolt Power supply outlet Inter-unit control wiring Unit: in. (mm) 15/32 - 43/64 (12 - 17) Full-scale installation diagram (printed on top of container box) Fig. 3-4 Unit: in. (mm) 10 73'@*OEPPS@64JOEC
![](/manual_guide/products/panasonic-s07md1u6-ecoivrf-systems-indoor-unit-installation-manual-eca925b/10.png)