Panasonic WU-144MF1U9E 3-Way Service Manual - Page 96

Mode Settings, Display of first 4 digits

Page 96 highlights

6. Mode Settings ■ Setting mode 1 ➀ Press and hold the (CHECK) button and (VENTILATION) button simultaneously for 4 seconds or longer. ➁ Use the temperature setting and buttons to change the item code. The item codes and setting data are shown in the table below. ➂ Use the timer time and buttons to change the setting data. To confirm the changed setting data, press the button. (At this time, " lit.) " stops blinking and remains ➃ During this mode, " " is displayed, blinking. The outdoor unit address display section displays "ALL," the item code number (DN value in the 3 table), and the setting data (8 digits). (The setting data is displayed in 8 digits. The display changes between the first 4 digits (Fig. A ) and the last 4 digits (Fig. B ). When the first 4 digits are displayed, the bottom dot of the colon is lit.) ➄ To exit the setting mode, press the button. (CHECK) 3-WAY VRF SYSTEM Outdoor Unit Maintenance Remote Controller A Display of first 4 digits 5 2 1 3 B Display of last 4 digits 5 2 1 3 A and B are displayed alternately. (Example shows display of 0000 0001.) DN Parameter Description Snowfall sensor usage 0 = Sensor input not present. Control is performed. 1 = Sensor input present. Control is performed. 2 = Sensor input not present. Control is not performed. 3 = Sensor input present. Control is not performed. Outdoor unit fan Quiet mode 0 = Disabled 2 = Quiet mode 2 4 = Quiet mode 4 1 = Quiet mode 1 3 = Quiet mode 3 Energy saving mode 0 = None 1 = Discharge temp. control only (Mode 3) 2 = Demand only (Mode 2) 3 = Discharge temp. control + Demand (Mode 1) Energy saving operation plug Demand 1 current 0 = Independent 1 = All indoor units linked 0 = 0% 1 = 40 ... 4 = 70 7 = 100 8 = 120 9 = 140 10 = 160 11 = 200 12 = -1 (no limit) Demand 2 current 0 = 0% 1 = 40 ... 4 = 70 7 = 100 8 = 120 9 = 140 10 = 160 11 = 200 12 = -1 (no limit) 3 - 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148

3
3
- 12
6. Mode Settings
3-WAY VRF SYSTEM
Outdoor Unit Maintenance Remote Controller
Setting mode 1
<Operating procedure>
Press and hold the
(CHECK) button and
(VENTILATION) button simultaneously for 4
seconds or longer.
Use the temperature setting
and
buttons to change the item code. The item codes
and setting data are shown in the table below.
Use the timer time
and
buttons to change
the setting data.
To confirm the changed setting data, press the
button.
(At this time, “
” stops blinking and remains
lit.)
During this mode, “
” is displayed, blinking.
The outdoor unit address display section displays
“ALL,” the item code number (DN value in the
table), and the setting data (8 digits).
(The setting data is displayed in 8 digits. The
display changes between the first 4 digits (Fig.
A
)
and the last 4 digits (Fig.
B
). When the first 4
digits are displayed, the bottom dot of the colon is
lit.)
To exit the setting mode, press the
(CHECK)
button.
5
3
1
2
A
Display of first 4 digits
DN
Parameter
Description
Snowfall sensor usage
0 = Sensor input not present. Control is performed.
1 = Sensor input present. Control is performed.
2 = Sensor input not present. Control is not performed.
3 = Sensor input present. Control is not performed.
Outdoor unit fan Quiet
mode
0 = Disabled
1 = Quiet mode 1
2 = Quiet mode 2
3 = Quiet mode 3
4 = Quiet mode 4
Energy saving mode
0 = None
1 = Discharge temp. control only (Mode 3)
2 = Demand only (Mode 2)
3 = Discharge temp. control + Demand (Mode 1)
Energy saving operation
plug
0 = Independent
1 = All indoor units linked
Demand 1 current
0 = 0%
1 = 40 … 4 = 70
7 = 100
8 = 120
9 = 140
10 = 160
11 = 200
12 = –1 (no limit)
Demand 2 current
0 = 0%
1 = 40 … 4 = 70
7 = 100
8 = 120
9 = 140
10 = 160
11 = 200
12 = –1 (no limit)
1
2
3
5
B
Display of last 4 digits
A
and
B
are displayed alternately.
(Example shows display of 0000 0001.)