Oki OKIPOS T400DT-Parallel Users Guide - Page 135

Serial Interface Parameters

Page 135 highlights

Serial Interface Parameters Command Structure Command Function Input to Printer Printer Output Special Notes I2abcde a = 0 Baud rate, 9600 bps 1 Baud Rate, 19200 bps 2 Baud Rate, 38400 bps 3 Baud Rate, 57600 bps b = 0 8 Data bits 1 7 Data Bits c = 0 No Parity 1 Odd Parity 2 Even Parity d = 0 1 Stop Bit 1 2 Stop Bits e = 0 Single Item Buffer 1 Multi Item Buffer 2 X-On/X-Off Flow Control 3 Bi-Com 4 4 Bi-Com 3 Example: See above Placement: Separate data stream sent to printer Default: Default value set by PG command To set the operating parameters of the RS232 Interface for a job. I230011 Z There is no printer output as a result of this command. 1. The setting are stored in the EEPROM by this command and they will remain in effect until a new I2 command is received. Cycling power will have no effect on these settings. 2. To change the value stored in the EEPROM, use the PG Printer Setting command or use the Printer Setting Utility program contained on the CDROM shipped with the printer. 3. All command parameters must be present in the data stream sent to the printer. 4. Selecting X-On/X-Off, Bi-Com3 or Bi-Com4 will automatically place the printer in the Multi Buffer mode. 126

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201

126
Serial Interface Parameters
Command Structure
<ESC>
I2abcde
a
=
0 Baud rate, 9600 bps
1 Baud Rate, 19200 bps
2 Baud Rate, 38400 bps
3 Baud Rate, 57600 bps
b
=
0 8 Data bits
1 7 Data Bits
c
=
0 No Parity
1 Odd Parity
2 Even Parity
d
=
0 1 Stop Bit
1 2 Stop Bits
e
=
0 Single Item Buffer
1 Multi Item Buffer
2 X-On/X-Off Flow Control
3 Bi-Com 4
4 Bi-Com 3
Example:
See above
Placement:
Separate data stream sent to printer
Default:
Default value set by <ESC>PG command
Command Function
To set the operating parameters of the RS232 Interface for a job.
Input to Printer
<ESC>
<ESC>
I230011
<ESC>Z
Printer Output
There is no printer output as a result of this command.
Special Notes
1.
The setting are stored in the EEPROM by this command and they will
remain in effect until a new <ESC>I2 command is received. Cycling power
will have no effect on these settings.
2.
To change the value stored in the EEPROM, use the <ESC>PG Printer
Setting command or use the Printer Setting Utility program contained on the
CDROM shipped with the printer.
3.
All command parameters must be present in the data stream sent to the
printer.
4.
Selecting X-On/X-Off, Bi-Com3 or Bi-Com4 will automatically place the
printer in the Multi Buffer mode.