Oki ES3640exMFPGA ES3640e MFP EFI Color Guide - Page 57
Calibrating the Fiery with the DTP41, Using the ColorWise Pro Tools Calibrator application and
View all Oki ES3640exMFPGA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 57 highlights
22-57 Calibrating the Fiery with the DTP41 When the patch has been measured successfully, a check mark appears in the patch preview in the Measurements window. The window identifies and highlights the next patch to be measured. 10. Repeat step 9 to measure each successive patch on the Measurement Page. Start with A1 and continue down Column A. When you have finished measuring all the patches in Column A, proceed to Column B in the same manner until all columns have been measured. To retake a measurement, select the desired patch preview in the Measurements window and measure the patch on the page using the ED-100. Note:You must take the measurements in the order outlined in the Measurements window and on the measurement page. 11. When all the patches have been read successfully, click Accept. 12. Click Apply in the Calibrator window to implement the new calibration set. 13. Click OK in the Information dialog box. Note:This completes the Fiery calibration process. Calibrating the Fiery with the DTP41 Using the ColorWise Pro Tools Calibrator application and the DTP41 spectrophotometer, you can quickly measure color patches printed by the ES3640e MFP and automatically download these measurements to the Fiery. Note:Before using ColorWise Pro Tools and the DTP41 to calibrate the Fiery, follow the instructions on page A-101 for calibrating the DTP41 spectrophotometer. ES3640e MFP Color Guide - 57