NEC NP-MC423W RS232 codes- Projectors - Page 70

[ 097-8. ECO MODE REQUEST ], Command, Response,  When the command succeeds, Data part,  When

Page 70 highlights

3.41 [ 097-8. ECO MODE REQUEST ] Gets the value set for the eco mode. Information Depending on the projector, the value for the "Light mode" or "Lamp mode" will be returned. Command 03h B0h 00h 00h 01h 07h BBh Response  When the command succeeds 23h B0h 02h 07h Data part Item DATA01 Value set for the eco mode Description Information For information about the values set for the eco mode, see the Appendix "Supplementary Information by Command".  When the command fails A3h B0h 02h ©NEC Display Solutions, Ltd. 2014-2020 70

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87

©NEC Display Solutions, Ltd. 2014-2020
70
3.41
[ 097-8. ECO MODE REQUEST ]
Gets the value set for the eco mode.
Information
Depending on the projector, the value for the "Light mode" or "Lamp mode" will be returned.
Command
03h
B0h
00h
00h
01h
07h
BBh
Response
When the command succeeds
23h
B0h
<ID1>
<ID2>
02h
07h
<DATA01>
<CKS>
Data part
Item
Description
DATA01
Value set for the eco mode
Information
For information about the values set for the eco mode, see the Appendix "Supplementary Information by
Command".
When the command fails
A3h
B0h
<ID1>
<ID2>
02h
<ERR1>
<ERR2>