NEC NP-MC423W RS232 codes- Projectors - Page 68

[ 079. FREEZE CONTROL ], Command, Data part, Response,  When the command succeeds,  When

Page 68 highlights

3.39 [ 079. FREEZE CONTROL ] Controls whether to turn the freeze function on or off. Command 01h 98h 00h 00h 01h Data part Item DATA01 Operation 01h 02h Response  When the command succeeds Description Turns the freeze function on. Turns the freeze function off. 21h 98h 01h Data part Item DATA01 Execution result 00h 01h Description Ended successfully. Ended with an error.  When the command fails A1h 98h 02h ©NEC Display Solutions, Ltd. 2014-2020 68

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87

©NEC Display Solutions, Ltd. 2014-2020
68
3.39
[ 079. FREEZE CONTROL ]
Controls whether to turn the freeze function on or off.
Command
01h
98h
00h
00h
01h
<DATA01>
<CKS>
Data part
Item
Description
DATA01
Operation
01h
Turns the freeze function on.
02h
Turns the freeze function off.
Response
When the command succeeds
21h
98h
<ID1>
<ID2>
01h
<DATA01>
<CKS>
Data part
Item
Description
DATA01
Execution result
00h
Ended successfully.
01h
Ended with an error.
When the command fails
A1h
98h
<ID1>
<ID2>
02h
<ERR1>
<ERR2>