Meade 14 inch Instruction Manual - Page 5

Automatic Alignment.

Page 5 highlights

ᕧ ᕩ ON/OFF HBX Port 7. Press the computer control panel power switch to OFF, if necessary. Remove the Autostar II handbox and the Autostar II coil cord from the packing materials. Plug one end into the HBX port of the telescope's computer control panel and plug the other end into the coil cord port on the Autostar II handbox. ấ OR ẩẪ 8. Attach microfocuser: Remove the dust cap from the rear cell port (A) of the telescope (Note: Telescope not shown for clarity). Thread the microfocuser adapter (B) into the rear cell port thread. Slide the microfocuser (C) over the microfocuser adapter and tighten the three hex screws on the microfocuser (K) using the provided hex keys. Important Note: The Microfocuser is shipped with the microfocuser adapter (B) threaded to the SC accessory adapter (L). Unthread the adapters from each other before attaching the microfocuser. Set aside the SC accessory adapter. For more information about the SC accessory adapter, see SC OPTIONAL ACCESSORY USERS, page 14. 1.25" Diagonal Prism Users: If using the 1.25" diagonal prism (G), slide the 1.25" adapter (D) into the microfocuser. Line up the thumbscrew into the groove in the microfocuser (I, also see Fig. 7a and 7b, page 14). Slide the 1.25" diagonal prism into the adapter (D). Tighten the adapter thumbscrew (H) to a firm feel only. Tighten the microfocuser thumbscrews (I) to a firm feel only. 2.0" Diagonal Mirror Users: If using the 2.0" diagonal mirror, slide the mirror directly into the microfocuser (C). Tighten the microfocuser thumbscrews (I) to a firm feel only. Display 9. Press the Power Switch on the computer control panel to the ON position. The copyright message lights on Autostar II's LCD display. µ Slew Speeds: Speed 9: Fast . . Speed 5: Medium . . Speed 1: Slow Arrow Keys Speed Key Number Keys 10. Press the key prompted by Autostar II to accept the Sun warning. Autostar II now displays "Automatic Alignment." You can then use the Arrow keys to slew (move) the telescope up, down, right, or left. To change the telescope's slew speed, press the Speed key and then the Number keys. "9" is the fastest speed and "1" is the slowest speed. See page 17 for more details. ¸ R.A. Lock Dec. Lock 11. Tighten, to a firm feel only, the R.A. and Dec. locks. Remove the dust cover from the end of the telescope tube. Place the Super Plössl 26mm eyepiece (F) into the diagonal prism (G) and tighten the attachment thumbscrew (E) to a firm feel only. Sight along the side of the telescope's main tube to locate an object. Rotate the mirror lock knob (9, Fig. 1) towards the "Unlock" position, until it feels loose-the telescope is shipped with the mirror locked. Use the telescope's coarse focus knob (6, Fig. 1) to bring the object into focus. Practice using the Autostar II Arrow keys to center an object in the telescope's field of view. 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

5
11.
Tighten, to a firm feel only, the R.A. and Dec.
locks. Remove the dust cover from the end of the
telescope tube.
Place the Super Plössl 26mm eyepiece (
F
) into
the diagonal prism (
G
) and tighten the attachment
thumbscrew (
E
) to a firm feel only.
Sight along the side of the telescope’s main tube
to locate an object. Rotate the mirror lock knob
(
9, Fig. 1
) towards the “Unlock” position, until it
feels loose—the telescope is shipped with the
mirror locked. Use the telescope’s coarse focus
knob (
6, Fig. 1
) to bring the object into focus.
Practice using the Autostar II Arrow keys to cen-
ter an object in the telescope’s field of view.
10.
Press the key prompted by Autostar II to accept
the Sun warning. Autostar II now displays
"Automatic Alignment."
You can then use the
Arrow keys to slew (move) the telescope up,
down, right, or left. To change the telescope’s slew
speed, press the Speed key and then the Number
keys. "9" is the fastest speed and "1" is the slow-
est speed. See page 17 for more details.
7.
Press the computer control panel power switch to
OFF, if necessary. Remove the Autostar II hand-
box and the Autostar II coil cord from the packing
materials. Plug one end into the HBX port of the
telescope's computer control panel and plug the
other end into the coil cord port on the Autostar II
handbox.
·
9.
Press the Power Switch on the computer control
panel to the ON position. The copyright message
lights on Autostar II's LCD display.
¸
Slew Speeds:
Speed 9: Fast
.
.
Speed 5: Medium
.
.
Speed 1: Slow
Arrow
Keys
Number
Keys
R.A.
Lock
Dec.
Lock
Display
±
²
³
´
µ
·
¸
¹
º
¹
8.
Attach microfocuser:
Remove the dust cap from
the rear cell port (
A)
of the telescope (Note:
Telescope not shown for clarity). Thread the micro-
focuser adapter (
B
) into the rear cell port thread.
Slide the microfocuser (
C
) over the microfocuser
adapter and tighten the three hex screws on the
microfocuser (
K
) using the provided hex keys.
Important Note:
The Microfocuser is shipped with the microfocuser
adapter (
B
) threaded to the SC accessory adapter (
L
).
Unthread the adapters from each other before attach-
ing the microfocuser. Set aside the SC accessory
adapter. For more information about the SC accessory
adapter, see
SC OPTIONAL ACCESSORY USERS
, page
14.
1.25" Diagonal Prism Users:
If using the 1.25"
diagonal prism (
G
), slide the 1.25" adapter (
D
) into
the microfocuser. Line up the thumbscrew into the
groove in the microfocuser (
I
, also see
Fig. 7a and
7b,
page 14). Slide the 1.25" diagonal prism into
the adapter (
D
). Tighten the adapter thumbscrew
(
H
) to a firm feel only. Tighten the microfocuser
thumbscrews (
I
) to a firm feel only.
2.0" Diagonal Mirror Users:
If using the 2.0" diag-
onal mirror, slide the mirror directly into the micro-
focuser (
C
). Tighten the microfocuser thumb-
screws (
I
) to a firm feel only.
»
Speed
Key
ON/OFF
HBX Port
¼
OR
º
»