LiftMaster LMSC1000 Installation Manual - English French Spanish

LiftMaster LMSC1000 Manual

LiftMaster LMSC1000 manual content summary:

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Introduction
The LiftMaster proprietary Long Range Reader and vehicle tags provide you
quick and easy access into your gate. The LiftMaster reader and vehicle tags
must be used as a system in order to function. The LiftMaster branded tags
can only be used with the LiftMaster branded reader.
LIFTMASTER LONG RANGE RFID READER
Model LMSC1000
WARNING:
This product can expose you to chemicals including
lead, which are known to the State of California to cause
cancer or birth defects or other reproductive harm. For more
information go to
www.P65Warnings.ca.gov.
Carton Inventory
Supported LiftMaster RFID tags
(Order Separately)
LMSC1000 RFID Reader
LMHNTG/SPLMHNTG*
LiftMaster RFID Hang tag
*
If specific Facility Code and Start ID required, use special part #s SPLMHNTG,
SPLMUNTG.
** The SW2 is not intended to be used on anything other than the LMSC1000.
LMUNTG/SPLMUNTG*
LiftMaster Dual-Purpose RFID
Tag (Windshield/Headlamp)
Mounting Bracket
S2W Wiegand Interface
Module
12V 3A Regulated Power
Supply
The S2W Wiegand Interface Module
and plug-in transformer shall
be mounted in either the CAPXL
enclosure or a Gate Operator Listed to
UL 325, or a weather proof enclosure:
UL Listed NITW or CYIV, Types 3X,
3RX, 3SX, 4X OR 6P.
U-Bolts (2)
Reader Specifications
Part Number
LMSC1000
FCC ID
XVY-IDRO900MA
Dimensions
10.25" x 10.25" x 1.5"
Polarization
Circular Polarized
Frequency range
902Mhz ~ 928 MHz
Supported Protocol
ISO 18000-6C/EPC C1 G2, ISO 18000-6B
Read Range
20 – 30 Feet (Depending on Tag)
Anti-Collision
Up to 100 tags/second
Environment
Operating Temp : - 20 C to + 50 C
Storage Temp : - 20 C to + 80 C
Connectivity
26-Bit Wiegand (D0, D1, GND)
RF Output Power
Adjustable 13-30 dBm with 1 dB steps
Power Accuracy +/- 0.5dBm
Weight
< 31.0 oz. (Reader Only)
Protocol
ISO18000-6C C1G2
Firmware
v.EI8070400
LMSC1000 input rating
12V DC, 700 mA
UL 294 Levels
Attack: I, Line Security: I, Endurance: IV,
Standby: I
S2W_001 electrical
ratings**
Input rating: 12 Vdc, 20 mA
Relay output rating:
24 Vdc, 1 A
Compatible UL Listed
control Panels
Chamberlain Group, Models CAPXL and
CAP2D
Model S2W is intended
to be installed within a
weather proof
enclosure
UL Listed NITW or CYIV, Types 3X, 3RX, 3SX,
4X, or 6P
LMHNTG
FC: 24
ID: 00025
Remove permit while vehicle is in motion.
07/18
07/18
FC: 24
ID: 000025
FC: 24
ID: 000025
LMUNTG Windshield/Headlamp Tag
NOTE:
UL verified compatibility with CAPXL and CAP2D. S2W-001 module
must be energized from either the Triad Magnetics, Model WSU120-3000
or C.SA Electronics (Dongguan) Co., Ltd Model CS1203000.