LiftMaster KPW250 KPW5 Manual - Page 4

Additional Programming - wireless keypad

Page 4 highlights

ADDITIONAL PROGRAMMING The Wireless Commercial Keypad must be put into programming mode prior to any of the programming steps below unless otherwise indicated. Set Temporary PIN A temporary 4-digit PIN can be programmed to allow access to visitors (maximum of 9 uses). The temporary PIN cannot be the same as any previously programmed PIN. The keypad will store up to 10 unique temporary PINs. Programming Step 1. Enter program mode 2. Set Temporary PIN 3. Exit Program Mode Keystroke Combination * (Master Code) # 05 # (New temporary 4-digit PIN) # (New temporary 4-digit PIN) # Number of uses (9 maximum) # * * # Indicator Long tone Long tone Keypad backlight will turn off Delete Permanent and Temporary PIN Programming Step 1. Enter program mode 2. Delete PIN 3. Exit Program Mode Keystroke Combination * (Master Code) # 07 # (4-digit PIN to be deleted) # (4-digit PIN to be deleted) # * * # Indicator Long tone Long tone Keypad backlight will turn off Reset Master Code Resetting the Master Code will not remove PINs or temporary PINs from memory and will not change the frequency and encryption type. After resetting the Master Code, the keypad will not operate any previously programmed operators until they are reprogrammed. To reset the Master Code to the factory default (888888): 1. Unlock and remove the faceplate. 2. Press and hold the RESET button on the control board for 6 seconds, a long tone sounds indicating the Master Code has been reset. Reset Keypad Resetting the keypad will erase the Master Code, all permanent PINs, all temporary PINs, and frequency and encryption settings. All settings will be set to factory default. After resetting, the keypad will not operate the previously programmed operators until they are reprogrammed. To reset the keypad: 1. Unlock and remove the faceplate. 2. Press and hold RESET button on the control board for 6 seconds until a long tone sounds then release. 3. Press and hold RESET button on the control board for 15 seconds, 3 long tones will sound indicating the keypad has been reset. Lockout Mode (Default is ON) If the keypad receives five consecutive invalid PINs, the keypad will enter lockout mode and will not accept any keypad inputs for 30 seconds. After 30 seconds, the keypad will begin accepting new inputs. Programming Step 1. Enter program mode 2. Set Lockout mode to ON: 3. Exit Program Mode Programming Step 1. Enter program mode 2. Set Lockout mode to OFF: 3. Exit Program Mode Keystroke Combination * (Master Code) # 02 # 1 # * * # Keystroke Combination * (Master Code) # 02 # 0 # * * # 4 Indicator Long tone Long tone Keypad backlight will turn off Indicator Long tone Long tone Keypad backlight will turn off

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

4
ADDITIONAL PROGRAMMING
The Wireless Commercial Keypad must be put into programming mode prior to any of the programming steps
below unless otherwise indicated.
Set Temporary PIN
A temporary 4-digit PIN can be programmed to allow access to visitors (maximum of 9 uses). The temporary
PIN cannot be the same as any previously programmed PIN. The keypad will store up to 10 unique temporary
PINs.
Delete Permanent and Temporary PIN
Reset Master Code
Resetting the Master Code will not remove PINs or temporary PINs from memory and will not change the
frequency and encryption type. After resetting the Master Code, the keypad will not operate any previously
programmed operators until they are reprogrammed. To reset the Master Code to the factory default (888888):
1. Unlock and remove the faceplate.
2.
Press and hold the RESET button on the control board for 6 seconds, a long tone sounds indicating the
Master Code has been reset.
Reset Keypad
Resetting the keypad will erase the Master Code, all permanent PINs, all temporary PINs, and frequency and
encryption settings. All settings will be set to factory default. After resetting, the keypad will not operate the
previously programmed operators until they are reprogrammed. To reset the keypad:
1. Unlock and remove the faceplate.
2.
Press and hold RESET button on the control board for 6 seconds until a long tone sounds then release.
3.
Press and hold RESET button on the control board for 15 seconds, 3 long tones will sound indicating the
keypad has been reset.
Lockout Mode (Default is ON)
If the keypad receives five consecutive invalid PINs, the keypad will enter lockout mode and will not accept any
keypad inputs for 30 seconds. After 30 seconds, the keypad will begin accepting new inputs.
Programming Step
Keystroke Combination
Indicator
1. Enter program mode
*
(Master Code)
#
Long tone
2. Set Lockout mode to
ON
:
02
#
1
#
Long tone
3. Exit Program Mode
*
*
#
Keypad backlight will turn off
Programming Step
Keystroke Combination
Indicator
1. Enter program mode
*
(Master Code)
#
Long tone
2. Set Lockout mode to
OFF
:
02
#
0
#
Long tone
3. Exit Program Mode
*
*
#
Keypad backlight will turn off
Programming Step
Keystroke Combination
Indicator
1. Enter program mode
*
(Master Code)
#
Long tone
2. Set Temporary PIN
05
#
(New temporary 4-digit PIN)
#
(New tempo-
rary 4-digit PIN)
#
Number of uses (9 maximum)
#
Long tone
3. Exit Program Mode
*
*
#
Keypad backlight will turn off
Programming Step
Keystroke Combination
Indicator
1. Enter program mode
*
(Master Code)
#
Long tone
2. Delete PIN
07
#
(4-digit PIN to be deleted)
#
(4-digit PIN to
be deleted)
#
Long tone
3. Exit Program Mode
*
*
#
Keypad backlight will turn off