LiftMaster KPW250 KPW5 Manual - Page 3

Program To Operator - programming

Page 3 highlights

PROGRAM TO OPERATOR Program to LiftMaster Operator NOTE: The Master Code and a PIN need to be set before the gate operator can be programmed. See Basic Programming, page 2. KPW5 - The frequency and encryption are set at the factory. Proceed to Step 4. KPW250 - The frequency and encryption are set at the factory for LiftMaster Security+ 2.0 (tri-band 310, 315, and 390 MHz) operators. Proceed to Step 4. For LiftMaster Security+ (315 MHz or 390 MHz), the frequency and encryption need to be set. Proceed to Step 1. * 1. Enter program mode: (Master Code) # 2 Set frequency and encryption (KPW250 only): • LiftMaster Security+ 315 MHz - Press 03 # 2 #. A long tone will sound. • LiftMaster Security+ 390 MHz - Press 03 # 3 #. A long tone will sound. • To reset factory default - Press 03 # 1 #. A long tone will sound. * * 3. Exit Program Mode: #. 4. Press the Learn Button on the operator. 5. Within 30 seconds - Enter a valid 4-digit PIN then press #. A long tone will sound. Program to Linear Multi-Code Receiver KPW250 ONLY 1. Locate the DIP switch sequence on the operator and record it. If DIP switch is in the "up" or "on" (CLOSED)position place a 1, "down" or "off" (OPEN) position place a 0 in the corresponding box in the chart below. DIP Switch Sequence UP / ON (CLOSED) DOWN / OFF (OPEN) 1 2 3 4 5 6 7 8 9 10 NOTE: Leave any unused switch locations blank. Write the DIP switch 10-digit sequence * 2. Enter program mode: (Master Code) #. A long tone will sound. 3. Set Linear Multi-Code frequency and encryption: Press 03 # 4 #. A long tone will sound. 4. Enter the DIP Switch sequence (Use ONLY 1 and 0). Press #. A long tone will sound. * * 5. Exit Program Mode: #. 6. Press the Learn Button on the operator. 7. Within 30 seconds - Enter a valid 4-digit PIN then press #. A long tone will sound. NOTE: When entering the DIP Switch sequence 3 beeps will sound if an incorrect number of entries is input. Once an operator has been programmed, enter a valid 4-digit PIN and the # key to activate the operator. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

3
Program to LiftMaster Operator
NOTE:
The Master Code and a PIN need to be set before the gate operator can be programmed. See Basic
Programming, page 2.
KPW5
-
The frequency and encryption are set at the factory.
Proceed to Step 4.
KPW250
-
The frequency and encryption are set at the factory for
LiftMaster Security+ 2.0
(tri-band 310,
315, and 390 MHz) operators.
Proceed to Step 4.
For
LiftMaster Security+
(315 MHz or 390 MHz), the frequency and encryption need to be set.
Proceed to Step 1.
1. Enter program mode:
*
(Master Code)
#
2
Set frequency and encryption (KPW250 only):
LiftMaster Security+ 315 MHz - Press
03
#
2
#
. A long tone will sound.
• LiftMaster Security+ 390 MHz - Press
03
#
3
#
. A long tone will sound.
• To reset factory default - Press
03
#
1
#
. A long tone will sound.
3. Exit Program Mode:
*
*
#.
4. Press the Learn Button on the operator.
5.
Within 30 seconds
- Enter a valid
4-digit PIN
then press
#. A long tone will sound.
PROGRAM TO OPERATOR
Program to Linear Multi-Code Receiver
KPW250 ONLY
1.
Locate the DIP switch sequence on the operator and record it. If DIP switch is in the “up” or “on”
(CLOSED)position place a 1, “down” or “off” (OPEN) position place a 0 in the corresponding box in the
chart below.
NOTE:
Leave any unused switch locations blank.
Write the DIP switch 10-digit sequence:
___ ___ ___ ___ ___ ___ ___ ___ ___ ___
2. Enter program mode:
*
(Master Code)
#.
A long tone will sound.
3.
Set Linear Multi-Code frequency and encryption: Press
03
#
4
#.
A long tone will sound.
4.
Enter the DIP Switch sequence (Use ONLY
1
and
0
).
Press
#.
A long tone will sound.
5. Exit Program Mode:
*
*
#.
6. Press the Learn Button on the operator.
7.
Within 30 seconds
- Enter a valid
4-digit PIN
then press #. A long tone will sound.
NOTE:
When entering the DIP Switch sequence 3 beeps will sound if an incorrect number of entries is input.
DIP Switch Sequence
1
2
3
4
5
6
7
8
9
10
UP / ON (CLOSED)
DOWN / OFF (OPEN)
Once an operator has been programmed, enter a valid 4-digit PIN and the # key to activate the operator.