LiftMaster HDSL24UL LiftMaster HDSL24UL HDSW24UL Wiring Diagram - English Fren - Page 1
LiftMaster HDSL24UL Manual
View all LiftMaster HDSL24UL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1 highlights
To reduce the risk of INJURY or DEATH: • Turn both the AC Power and Battery switches to OFF position BEFORE installing or servicing operator. • Replace ONLY with fuse of same type and rating. • To be compliant with UL325 and industry safety guidelines, qualified monitored external entrapment protection devices such as photoelectric sensors or edge sensors are required to be installed with this operator at each entrapment zone. Use ONLY LiftMaster approved entrapment protection devices (refer to the accessory page of manual). • See manual prior to servicing regarding maintenance and required safety testing. Diagnostic Codes TO VIEW THE CODES: Press and hold STOP... ...then press and hold CLOSE... ...then press and hold OPEN until "Er" shows. The operator will show the code sequence number followed by the code number: A SECOND LATER.... CODE SEQUENCE NUMBER The first number shown is the most recent code (example: "01"). The display will show the sequence of codes that occurred starting with "01" and going up to code "20". CODE COLOR KEY: LiftMaster System Installed System Informational CODE NUMBER The second number shown after the code sequence number is the code itself (31-99, example" "31"). External Entrapment Protection Inherent Entrapment Protection CODE 31 34 35 36 37 38 40 41 42 43 44 45 46 47 48 50* 53 54 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 80 81 82 83 84 91 93 95 96 99 MEANING SOLUTION Control board has experienced an internal failure. Disconnect all power, wait 15 seconds, then reconnect power (reboot). If issue continues, replace main control board. Absolute Position Encoder error, not getting position information from encoder Check APE assembly and wiring connections. Replace the APE assembly if necessary. Max-run-time exceeded error Check for an obstruction, then reprogram the limits. Product ID error Was the control board just replaced? If so, erase limits, enter limit setup mode and set limits. If not, disconnect all power, wait 15 seconds, then reconnect power before changing product ID harness. Product ID failure Unplug product ID harness then plug back in. Disconnect all power, wait 15 seconds, then reconnect power before replacing product ID harness. Hard stop limit (Arm 1) Limit may be set too tightly against a nonresilient hard stop (re-adjust limit). Operator may be at end of travel (re-adjust mounting). Battery overvoltage Too much voltage on the battery. Check harness. Make sure there is NOT a 24V battery on a 12V system. Battery overcurrent Possible short of the battery charge harness. Check harness. Make sure you do NOT have a 12V battery on a 24V system. No battery at boot up Check battery connections and installation. Replace batteries if depleted to less than 20V on a 24V system or less than 10V on a 12V system. Make sure there is NOT a single 12V battery on a 24V system. Exit loop error Shadow loop error Interrupt loop error Failure or missing loop (SHORT or OPEN LiftMaster Plug-in Loop Detector only). Check loop wiring throughout connection. May be a short in the loop, or an open connection in the loop. Wireless edge battery low Replace batteries in wireless edge. Motor Drive Fault Check motor drive connections. Disconnect all power, wait 15 seconds, then reconnect power (reboot). If issue persists, replace motor. Hall Sensor Fault Check motor and motor drive connections. Disconnect all power, wait 15 seconds, then reconnect power (reboot). If issue persists, replace motor. Gate overspeed detected *Note: Code 50 only applies to Slide gate operators. Make sure the gate is installed on a level surface and not on an excessive grade. Brownout occurred AC/DC board supply dipped below allowable level. Review power supply and wiring. If rebooting, ensure enough time for discharge of power to force a fresh boot. Wireless second operator communication error Check the second operator for power. If OFF, restore power and try to run the system. If powered, deactivate the wireless feature and then re-learn the second operator. Minimum number of monitored entrapment protection devices not installed. Review monitored entrapment protection device connections. Slide gate operators require a minimum of two external safety devices; one in the close and one in the open direction. CLOSE EYE/INTERRUPT held more than 3 minutes CLOSE EDGE held more than 3 minutes Check wired input on main control board; check for alignment or obstruction. OPEN EYE/EDGE held more than 3 minutes CLOSE EYE/INTERRUPT held more than 3 minutes Check wired input on expansion board; CLOSE EYE/EDGE held more than 3 minutes check for alignment or obstruction. OPEN EYE/EDGE held more than 3 minutes Wireless edge triggered more than 3 minutes Check wired input for wiring issue or obstruction. Wireless edge loss of monitoring Check wireless edge inputs. Wireless edge triggered IF an obstruction occurred, no action required. If an obstruction did NOT occur, check inputs and wiring. CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC CLOSE EDGE triggered, causing reversal, NO preventing close, or canceling TTC OPEN EYE/EDGE triggered, causing reversal or preventing opening IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC CLOSE EYE/EDGE triggered, causing reversal and preventing close or canceling TTC OPEN EYE/EDGE triggered, causing reversal or preventing opening IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board. Close input (EYE/EDGE) communication fault from other operator Open input (EYE/EDGE) communication fault from other operator Check inputs and communication method between operators, either wired bus or radio. Ensure operator is powered. May have to erase the wireless communication and reprogram the two operators. Close input (EYE/EDGE) communication fault (expansion board) Open input (EYE/EDGE) communication fault (expansion board) Check the connections between the main board and the expansion board. Non-monitored device detected on the wireless safety system Non-monitored contact closure devices are not supported. Make sure connected devices are monitored. Check edges for proper orientation and resistive end cap connection. Force reversal (Operator 1) Check for obstruction. If no obstruction, check that the mechanical assembly is engaged and free to move. See Limit, Speed and Force Adjustment page 23. RPM / STALL reversal (Operator 1) Check for obstruction. If no obstruction, check the operator wiring and that the mechanical assembly is engaged and free to move. Replace APE assembly. Motor start failure Operator attempted to run, no response from motor drive assembly. Check connector and harness. If connected properly and still not working, replace motor and/or motor drive. Power Board Fault Check connections to power board. Power cycle and retry. Replace power board if issue persists. Normal operation No action required SAVED NO YES YES YES YES NO YES YES YES YES YES YES YES YES YES YES NO YES YES YES YES NO NO NO YES YES YES YES YES YES YES YES CONTROL BOARD ANTENNA POWER BOARD MECHANICAL INTERLOCK (For slide version only) POWER BOARD RESET SWITCH PRODUCT ID ALARM ACCESSORY DUAL ENTRAPMENT POWER LOCKS GATES PROTECTION LOOPS CONTROLS WIRING DIAGRAM Models HDSL24UL and HDSW24UL Jumper N.C. OPEN and COM: Hard Open (line-of-sight) CLOSE and COM: Hard Close (line-of-sight) STOP and COM: Hard Stop(line-of-sight) EXIT: Soft Open (used for exit probe, telephone entry, external exit loop detector, or any device that would command the gate to open) EXIT LOOP PHOTOELECTRIC SENSORS for CLOSE cycle SHADOW LOOP EDGE SENSOR for CLOSE cycle PHOTOELECTRIC SENSORS or EDGE SENSOR for OPEN cycle Shielded Twisted Pair Cable (Primary/Secondary link to other gate operator) Ground the shield of the cable to the chassis ground of each operator. POWER SW 24 VDC 1 A Maximum ACCESSORY ON POWER 24 VDC 1 A Maximum 12V SOLAR PANELS IN SERIES APS ENCODER MOTOR DRIVE BLDC MOTOR SHADOW LOOP INTERRUPT LOOP PLUG-IN LOOP DETECTOR Model LOOPDETLM EXIT LOOP EXPANSION BOARD N.C. JUMPER THREE BUTTON STATION Control function of Auxiliary Relays Control function of photoelectric sensor or edge sensor for the OPEN or CLOSE cycle. HEATER KIT CONTROL PWR IN PWR OUT 30A 32V DC PWR FUSES RELAY ADAPTER BOARD PHOTOELECTRIC SENSORS PHOTOELECTRIC SENSORS Red or EDGE SENSORS Black DC PWR 30A 32V DC PWR FUSES BAT BATTERY SWITCH 12V BATTERIES IN SERIES POWER ADAPTER BOARD INPUT POWER CONNECTION BRIDGE RECTIFIER AC POWER SWITCH TRANSFORMER EMI BOARD SINGLE BUTTON CONTROL STATION LiftMaster.com © 2019, LiftMaster All Rights Reserved 01-39240-13C