LiftMaster CSW24V CSW24V Manual - Page 22
Connect Batteries, 33ah Batteries
View all LiftMaster CSW24V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
WIRING CONNECT BATTERIES 33AH BATTERIES The batteries are charged in the circuit by the integrated transformer. The batteries are for battery backup or solar installation. The 33AH application requires the 33AH battery harness (Model K94-36596). NOTE: If 33AH batteries (2) are used, the battery tray will need to be removed to allow more space in the enclosure. 1 Disconnect the red (+) and black (-) wires going from the bridge rectifier to the J15 plug labeled DC POWER on the control board. 2 Connect the red (+) and black (-) wires from the new 33AH harness to the bridge rectifier. 3 Connect a jumper between the positive (+) terminal of one battery to the negative (-) terminal of the other battery. 4 Connect the red wire from the J15 plug to the positive (+) terminal of the battery. 5 Connect the black wire from the J15 plug to the negative (-) terminal of the battery. 6 Turn ON AC power to the operator. 7 Turn ON the AC power switch on the operator. 8 Plug the J15 plug back into the control board. CONNECT BATTERIES (without heater) (with heater) -+ -- Bridge Rectifier Black (-) Red (+) J15 Plug Red (+) Black (-) 33AH Batteries 20