SETTINGS DUAL GATE SETTINGS NOTE: We recommend that all accessories and board configurations are set on the primary operator. MAIN CONTROL BOARD FEATURE PRIMARY OPERATOR Timer-to-Close Set the TTC dial to desired setting OFF SECONDARY OPERATOR Bi-Part Delay Switch Bi-Part Delay: ON (will open last and close first) Tandem Mode: OFF Bi-Part Delay: OFF (will open first and close last) Tandem Mode: OFF ACCESSORY Remote Controls LiftMaster Internet Gateway Garage and Gate Monitor PRIMARY OPERATOR Program remote controls 1 to 50 to the primary operator. Program to primary operator. SECONDARY OPERATOR Program remote controls 51 to 100 to the secondary operator Program to primary operator. EXPANSION BOARD FEATURE QUICK CLOSE Switch ANTI-TAIL Switch PRIMARY OPERATOR ON ON SECONDARY OPERATOR OFF OFF WIRING SAMS WIRING WITH RELAYS NOT ENERGIZED Control Board BIPART DELAY 4 2 6 OPEN LEFT OPEN 8 RIGHT HANDING Exit Input Barrier Arm Operator C Auxiliary Command NO COMM LINK BA CLASS 2 SUPPLY 24 VAC 500 mA MAX GND ANTENNA CURRENT MOTOR DRIVE SENSOR ID RESET RPM & LIMITS ALARM EXP. BOARD 24 VAC IN Expansion Board POWER TO MAIN BOARD SHADOW INTERUPT EXIT OPEN CLOSE DEVICE INPUTS 1 EYE ONLY 2 EYE/ EDGE 3 EYE/ EDGE COM SBC OPN CLS STP COM Shadow Input Access Device Dipswitch settings for AUX Relay 1: 1-OFF, 2-OFF, 3-ON AUX Relay 1 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

19
SETTINGS
SAMS WIRING WITH RELAYS NOT ENERGIZED
FEATURE
PRIMARY OPERATOR
SECONDARY OPERATOR
QUICK CLOSE Switch
ON
OFF
ANTI-TAIL Switch
ON
OFF
EXPANSION BOARD
FEATURE
PRIMARY OPERATOR
SECONDARY OPERATOR
Timer-to-Close
Set the TTC dial to desired setting
OFF
Bi-Part Delay Switch
Bi-Part Delay: ON (will open last and close first)
Tandem Mode: OFF
Bi-Part Delay: OFF (will open first and close last)
Tandem Mode: OFF
DUAL GATE SETTINGS
NOTE:
We recommend that all accessories and board configurations are set on the primary operator.
MAIN CONTROL BOARD
ACCESSORY
PRIMARY OPERATOR
SECONDARY OPERATOR
Remote Controls
Program remote controls 1 to 50 to the primary operator.
Program remote controls 51 to 100 to the secondary operator
LiftMaster Internet
Gateway
Program to primary operator.
Garage and Gate
Monitor
Program to primary operator.
COMM
LINK
B
A
BIPART
DELAY
2
4
6
8
HANDING
OPEN
LEFT
OPEN
RIGHT
ANTENNA
CURRENT
SENSOR
MOTOR DRIVE
RPM & LIMITS
ALARM
EXP.
BOARD
24 VAC IN
ID RESET
GND
SHADOW
INTERUPT
EXIT
SBC
OPN
CLS
STP
COM
EYE
ONLY
EYE/
EDGE
EYE/
EDGE
COM
1
2
3
OPEN
CLOSE
TO MAIN
BOARD
POWER
Access Device
Exit Input
Shadow Input
AUX Relay 1
C
NO
Auxiliary
Command
Dipswitch settings for AUX
Relay 1: 1-OFF, 2-OFF, 3-ON
Control Board
Expansion Board
Barrier Arm Operator
WIRING