Operator Specifications, External Entrapment Protection Device Inputs non-contact
View all LiftMaster CSL24ULWK manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
INTRODUCTION Operator Specifications Usage Classification Class I, II, III, & IV Main AC Supply 120 Vac, 4 Amps (10 Amps including Accessory Outlets) OR 240 Vac, 2 Amps When Optional Transformer Kit Model 3PHCONV is installed in the field, operator is rated 208/240/480/575 VAC, 4.8/4.2/2.1/1.7 A, 60 Hz, 1 PH System Operating Voltage 24 Vdc Transformer Run / Battery Backup Accessory Power 24 Vdc, 500mA max. for ON + SW (switched) Solar Power Max 24 Vdc at 60 watts max. Maximum Gate Weight 1500 lbs. (680.4 kg) Minimum Gate Travel Distance 4 feet (1.2 m) Maximum Gate Travel Distance 50 feet (15.24 m) Maximum Gate Travel Speed 1 foot/second Maximum Daily Cycle Rate Continuous Maximum Duty Cycle Continuous Operating Temperature Without Heater: -20°C to 60°C (-4°F to 140°F) With Optional Heater: -40°C to 60°C (-40°F to 140°F) Expansion Board Provided External Entrapment Protection Device Inputs (non-contact Main board - up to 2 close entrapment protection devices and 1 open entrapment and/or contact) protection device. Expansion board - up to 3 entrapment protection devices configurable to either close or open and up to 4 edge sensors using wireless edge sensor kit model LMWEKITU . 7