Lantronix XPort Direct Demonstration Kit XChip Direct - User Guide - Page 30

Manual Connection Address Example, Autostart Automatic, Connection, Autostart, Hostlist

Page 30 highlights

6: Setup Mode: Channel Configuration Figure 6-2. Manual Connection Address Example Command String C121.2.4.5/1 C5 Result if remote IP is 129.1.2.3 and remote port is 1234 Complete override; connection is started with host 121.2.4.5, port 1. Connects to 129.1.2.5, port 1234. C28.10/12 Connects to 129.1.28.10, port 12. C0.0.0.0/0 Enters Monitor Mode. Autostart (Automatic Connection) Hostlist If you enable Autostart, the unit automatically connects to the remote IP address and remote port specified when the firmware starts. If you enable this option, the XPort Direct scrolls through the hostlist until it connects to a device listed in the hostlist table. Once it connects, the unit stops trying to connect to any others. If this connection fails, the unit continues to scroll through the table until it is able to connect to another IP in the hostlist. Hostlist supports a minimum of 1 and a maximum of 12 entries. Each entry contains the IP address and the port number. The hostlist is disabled for Manual and Modem Modes. The unit does not accept a data connection from a remote device when the hostlist option is enabled. Figure 4-7. Hostlist Option DeviceLinx™ XPort Direct/XChip Direct SoC User Guide 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

6: Setup Mode: Channel Configuration
DeviceLinxâ„¢
XPort Direct/XChip Direct SoC User Guide
30
Figure 6-2. Manual Connection Address Example
Command String
Result if remote IP is 129.1.2.3 and remote port is
1234
C121.2.4.5/1
Complete override; connection is started with host 121.2.4.5,
port 1.
C5
Connects to 129.1.2.5, port 1234.
C28.10/12
Connects to 129.1.28.10, port 12.
C0.0.0.0/0
Enters Monitor Mode.
Autostart (Automatic
Connection)
If you enable
Autostart
, the unit automatically connects to the
remote IP address and remote port specified when the firmware
starts.
Hostlist
If you enable this option, the XPort Direct scrolls through the
hostlist until it connects to a device listed in the hostlist table.
Once it connects, the unit stops trying to connect to any others. If
this connection fails, the unit continues to scroll through the table
until it is able to connect to another IP in the hostlist.
Hostlist supports a minimum of 1 and a maximum of 12 entries.
Each entry contains the IP address and the port number.
The hostlist is disabled for Manual and Modem Modes. The unit
does not accept a data connection from a remote device when
the hostlist option is enabled.
Figure 4-7. Hostlist Option