Kenwood TM-G707A User Manual - Page 45
Scan Resume Methods
View all Kenwood TM-G707A manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
SCAN RESUME METHODS Before using Scans other than Priority Scan, it's necessary to decide under what condition you want your transceiver to continue scanning after detecting and stopping for a signal. You can choose Time-Operated mode or Carrier-Operated mode. The default is TimeOperated mode. • Time-Operated mode Your transceiver stops scanning when detecting a signal, remains there for approximately 5 seconds, and then continues to scan even if the signal is still present. • Carrier-Operated mode Your transceiver stops scanning when detecting a signal and remains on the same frequency until the signal drops out. There is a 2 second delay between signal drop-out and scan resumption to allow time for any responding stations to begin transmitting. Note: To temporarily stop scanning and monitor weak signals, press and hold the Mic PF key assigned the Monitor function {page 51}. Release the key to resume scanning. ■ Selecting Scan Resume Method 1 Press [MNU] to enter Menu mode. 1 2 Select Menu No. 10 (SCAN). 2 3 4 5 6 7 3 Press [OK], then select Time-Operated (default) 8 or Carrier-Operated. 9 10 11 12 2 1 13 4 Press [OK] again to complete the setting and exit 14 Menu mode. 15 16 17 18 19 20 21 22 39