Honeywell HM506DG115 Installation Guide - Page 36

A: Specifications - truesteam 6 gallon humidifier

Page 36 highlights

A: Specifications Humidifying Capacity HM506: up to 6 gallons per day (gpd) (23 liters per day [lpd]) HM509: up to 9 gpd (34 lpd) HM512: up to 12 gpd (45 lpd) Humidified Area HM506: 4,000-14,400 cubic feet HM509: 8,000-18,400 cubic feet HM512: 12,000-24,000 cubic feet Note: Higher volumes require more TrueSTEAM run time. Weight HM506: HM509: HM512: Empty 8 lbs. 8 lbs. 9 lbs. Filled with Water 12 lbs. 15 lbs. 15 lbs. Dimensions 11-1/4 in. W x 19 in. H x 9 in. D Operating Temperature Range • TrueSTEAM Humidifier: 34ºF-104ºF (1.1ºC-40ºC) • Remote Hose/Nozzle: -50ºF-250ºF (-46ºC-121ºC) • Operating Humidity Range: 0-95% RH, non-condensing Drain Operation • Automatic Flush Schedule: Configurable to 8, 12, 20, or 30 hours of operational time (heating element active) • Automatic Flush Cycle Time: Flush cycle takes approximately 45 minutes to empty the tank completely • Draining Temperature Range: 34ºF-212ºF (1.1ºC-100ºC) Electrical Ratings and Tolerances Input Ratings • Power Supply: 120VAC +10-15%, 60Hz - HM506: 840W at 120VAC at full load - HM509: 1200W at 120VAC at full load - HM512: 1440W at 120VAC at full load • HM506: 7A, 120VAC • HM509: 10A, 120VAC • HM512: 12A, 120VAC • 15A, 120VAC interlock switch • Thermostat/HVAC power monitor (R to C): 10mA resistive at 24VAC • Field wiring terminals: 18-22 ga. Solid • HVAC power/airflow monitor: 10 mA resistive at 24 VAC Output Ratings • Relay output contacts: - Fan: 1.5A full load, 7.5A locked rotor at 24VAC - Heat and backup: 15A resistive at 120VAC • Fill Solenoid: 0.1A at 120VAC, 0.5 PF • Drain Solenoid: 0.1A at 120VAC, 0.5PF • Humidistat output contacts: 10mA resistive at 24VAC • Humidistat power supply: 100mA at 24VAC Standards and Approval Body Requirements • Underwriters Laboratories: UL998, File no. E185662 • Federal Communications Commission: Class B compliance, File no. YU555 • Intended to be used in accordance with the National Electrical Code (NEC), ANSI/NFPA 70, and the rules of the Canadian Electrical Code (CEC), Part 1, C22.1 APPENDICES 34 TrueSTEAM Humidification System 69-2285EF-01

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92

APPENDICES
TrueSTEAM Humidification System
69-2285EF—01
34
Humidifying Capacity
HM506: up to 6 gallons per day (gpd)
(23 liters per day [lpd])
HM509: up to 9 gpd (34 lpd)
HM512: up to 12 gpd (45 lpd)
Humidified Area
HM506: 4,000–14,400 cubic feet
HM509: 8,000–18,400 cubic feet
HM512: 12,000–24,000 cubic feet
Note: Higher volumes require more TrueSTEAM run time.
Weight
Empty
Filled with Water
HM506:
8 lbs.
12 lbs.
HM509:
8 lbs.
15 lbs.
HM512:
9 lbs.
15 lbs.
Dimensions
11-1/4 in. W x 19 in. H x 9 in. D
Operating Temperature Range
TrueSTEAM Humidifier: 34ºF–104ºF (1.1ºC–40ºC)
Remote Hose/Nozzle: -50ºF–250ºF (-46ºC–121ºC)
Operating Humidity Range: 0–95% RH, non-condensing
Drain Operation
Automatic Flush Schedule: Configurable to 8, 12, 20, or
30 hours of operational time (heating element active)
Automatic Flush Cycle Time: Flush cycle takes
approximately 45 minutes to empty the tank completely
Draining Temperature Range: 34ºF–212ºF (1.1ºC–100ºC)
Electrical Ratings and Tolerances
Input Ratings
Power Supply: 120VAC +10-15%, 60Hz
- HM506: 840W at 120VAC at full load
- HM509: 1200W at 120VAC at full load
- HM512: 1440W at 120VAC at full load
HM506: 7A, 120VAC
HM509: 10A, 120VAC
HM512: 12A, 120VAC
15A, 120VAC interlock switch
Thermostat/HVAC power monitor (R to C):
10mA resistive at 24VAC
Field wiring terminals: 18–22 ga. Solid
HVAC power/airflow monitor: 10 mA resistive at 24 VAC
Output Ratings
Relay output contacts:
- Fan: 1.5A full load, 7.5A locked rotor at 24VAC
- Heat and backup: 15A resistive at 120VAC
Fill Solenoid: 0.1A at 120VAC, 0.5 PF
Drain Solenoid: 0.1A at 120VAC, 0.5PF
Humidistat output contacts: 10mA resistive at 24VAC
Humidistat power supply: 100mA at 24VAC
Standards and Approval Body Requirements
Underwriters Laboratories: UL998, File no. E185662
Federal Communications Commission: Class B
compliance, File no. YU555
Intended to be used in accordance with the
National Electrical Code (NEC), ANSI/NFPA 70,
and the rules of the Canadian Electrical Code (CEC),
Part 1, C22.1
A: Specifications