HP XP P9500 HP StorageWorks P9000 RAID Manager Reference Guide (T1610-96034, M - Page 182
raidcom modify rcu, Syntax, F: FIBRE, E:ESCON
View all HP XP P9500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 182 highlights
This displays the CU number (hexadecimal) as MCU. If CU free is specified for RCU, "-" is displayed. -RCU This displays the CU number (hexadecimal) as RCU. If CU free is specified for RCU, "-" is displayed. -M/R This displays the CU type as MCU/RCU. -T This displays the type of physical path. F: FIBRE, E:ESCON, -PNO This displays the path number. -MPORT This displays the MCU port number. -RPORT This displays the RCU port number. -STS_CD This displays the following status of the path. - NML_01: this means the status of "Normal" in path. - ERR_02: this means the status of "Initialization Failed" in path. - ERR_03: this means the status of "Communication timeout" in path. - ERR_04: this means the status of "Logical Blockade" in path. - ERR_05: this means the status of "Resource Shortage" in path. - ERR_06: this means the status of "Serial Number Mismatch" in path. - ERR_10: this means the status of "Invalid Port" in path. - ERR_80: this means the status of "RCU Port Number Mismatch" in path. - ERR_81: this means the status of "RCU Port Type Mismatch" in path. - ERR_82: this means the status of "Communication Failed" in path. -SSIDs This displays the SSIDs (hexadecimal) setting to RCU. If CU free is specified for RCU, "-" is displayed. raidcom modify rcu Sets the control parameters to CU that is specified using two way. Syntax raidcom modify rcu -cu_free -rcu_option 182 Configuration setting commands