HP R1.5 UPS R12000 XR Models User Guide - Page 30

Alarms, Table 3-2

Page 30 highlights

LCD Configuration and Status Alarms If an alarm exists, one or more of the following alarms will display on the LCD panel. For a descriptive list of alarm causes, refer to the section, "LCD Alarm Troubleshooting," in Chapter 5. Table 3-2: Alarms Ambient Over Temperature Automatic Shutdown Pending Batteries Disconnected Battery DC Over Voltage Battery Low Battery n Needs Service Battery Not Charged Battery n Test Failed Bypass Not Available Calibration Failed DC Link Over Voltage Fan Failure Fuse Failure Heatsink Over Temperature Input AC Over Voltage Input AC Under Voltage Input Under Or Over Frequency Internal Communications Failure Inverter Contactor Open Inverter Fault Inverter Output Over Current Inverter Startup Failure Inverter Uncalibrated Level 2 Overload - Phase A Level 3 Overload - Phase A Level 4 Overload - Phase A Loss of Redundancy Loss of Sync-Bus Low Battery Shutdown Non-volatile Memory Checksum Fail On Manual Bypass Output AC Over Voltage Output AC Under Voltage Output Overload Program Checksum Fail Rectifier Input Over Current Remote Emergency Power Off Software Incompatibility Detected UPS On Battery UPS On Bypass Utility Fail Utility Not Present 3-6 HP Uninterruptible Power System R12000 XR Models User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

LCD Configuration and Status
Alarms
If an alarm exists, one or more of the following alarms will display on the LCD panel. For a
descriptive list of alarm causes, refer to the section, “LCD Alarm Troubleshooting,” in
Chapter 5.
Table 3-2:
Alarms
Ambient Over Temperature
Inverter Startup Failure
Automatic Shutdown Pending
Inverter Uncalibrated
Batteries Disconnected
Level 2 Overload – Phase A
Battery DC Over Voltage
Level 3 Overload – Phase A
Battery Low
Level 4 Overload – Phase A
Battery
n
Needs Service
Loss of Redundancy
Battery Not Charged
Loss of Sync-Bus
Battery
n
Test Failed
Low Battery Shutdown
Bypass Not Available
Non-volatile Memory Checksum Fail
Calibration Failed
On Manual Bypass
DC Link Over Voltage
Output AC Over Voltage
Fan Failure
Output AC Under Voltage
Fuse Failure
Output Overload
Heatsink Over Temperature
Program Checksum Fail
Input AC Over Voltage
Rectifier Input Over Current
Input AC Under Voltage
Remote Emergency Power Off
Input Under Or Over Frequency
Software Incompatibility Detected
Internal Communications Failure
UPS On Battery
Inverter Contactor Open
UPS On Bypass
Inverter Fault
Utility Fail
Inverter Output Over Current
Utility Not Present
3-6
HP Uninterruptible Power System R12000 XR Models User Guide