Page 6 highlights
6. Check the cleaning station wiper and verify the 2mm spacer exist inside the wiper assembly. If not, order a new wiper assembly (refer to the parts catalog). Figure 2-1 2 mm spacer inside cleaning station wiper assembly 7. Check that the cleaning station return hose O ring & V seal ring are installed properly and are not damaged. Figure 2-2 Cleaning station inlet pipe with V-seal and O-ring 1 V-seal 2 O-ring Figure 2-3 V-seal on cleaning station inlet pipe 1 Rear wall of press 2 Cleaning station inlet pipe 3 V-seal - 0905-1593 4 Chapter 2 Procedures
6.
Check the cleaning station wiper and verify the 2mm spacer exist inside the wiper assembly. If not, order
a new wiper assembly (refer to the parts catalog).
Figure 2-1
2 mm spacer inside cleaning station wiper assembly
7.
Check that the cleaning station return hose O ring & V seal ring are installed properly and are not
damaged.
Figure 2-2
Cleaning station inlet pipe with V-seal and O-ring
1
V-seal
2
O-ring
Figure 2-3
V-seal on cleaning station inlet pipe
1
Rear wall of press
3
V-seal – 0905-1593
2
Cleaning station inlet pipe
4
Chapter 2
Procedures