6. Check the cleaning station wiper and verify the 2mm spacer exist inside the wiper assembly. If not, order a new wiper assembly (refer to the parts catalog). Figure 2-1 2 mm spacer inside cleaning station wiper assembly 7. Check that the cleaning station return hose O ring & V seal ring are installed properly and are not damaged. Figure 2-2 Cleaning station inlet pipe with V-seal and O-ring 1 V-seal 2 O-ring Figure 2-3 V-seal on cleaning station inlet pipe 1 Rear wall of press 2 Cleaning station inlet pipe 3 V-seal - 0905-1593 4 Chapter 2 Procedures

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

6.
Check the cleaning station wiper and verify the 2mm spacer exist inside the wiper assembly. If not, order
a new wiper assembly (refer to the parts catalog).
Figure 2-1
2 mm spacer inside cleaning station wiper assembly
7.
Check that the cleaning station return hose O ring & V seal ring are installed properly and are not
damaged.
Figure 2-2
Cleaning station inlet pipe with V-seal and O-ring
1
V-seal
2
O-ring
Figure 2-3
V-seal on cleaning station inlet pipe
1
Rear wall of press
3
V-seal – 0905-1593
2
Cleaning station inlet pipe
4
Chapter 2