HP Indigo W7200 Blanket Creep Diagnosis and Correction - Page 4

Special jigs and tools, For second transfer (T2) and top dead point (TDP) calibration

Page 4 highlights

2 Special jigs and tools Graduated bubble level - accurate to 0.1 mm Flashlight Small telescopic mirror Tie-wraps (300 mm or longer) (x5) Web Handling System (WHS) in the Printing Engine Service Document (CA393-00590) For second transfer (T2) and top dead point (TDP) calibration Follow these steps for the second transfer and top dead point calibration. 1. Cut blanket - remove 15mm from both blanket sides Figure 2-1 Cut blanket, 15mm were removed from both blanket sides 2. TDP calibration jig CA045-15732 Figure 2-2 TDP jig CA045-15731 3. Filler gages single leaf set with 0.75 and 0.8 gages included in the set Figure 2-3 Feeler gauge set 2 Chapter 2 Special jigs and tools

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29

Special jigs and tools
2
Graduated bubble level - accurate to 0.1 mm
Flashlight
Small telescopic mirror
Tie-wraps (300 mm or longer) (x5)
Web Handling System (WHS) in the Printing Engine Service Document
(CA393-00590)
For second transfer (T2) and top dead point (TDP) calibration
Follow these steps for the second transfer and top dead point calibration.
1.
Cut blanket – remove 15mm from both blanket sides
Figure 2-1
Cut blanket, 15mm were removed from both blanket sides
2.
TDP calibration jig CA045-15732
Figure 2-2
TDP jig CA045-15731
3.
Filler gages single leaf set with 0.75 and 0.8 gages included in the set
Figure 2-3
Feeler gauge set
2
Chapter 2
Special jigs and tools