HP D2D4009fc HP StoreOnce B6200 Backup System User Guide (BB877-90910, Novembe - Page 205
Node warning SNMP messages, Network switch SNMP warning messages, Ibrix SNMP warning messages
View all HP D2D4009fc manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 205 highlights
Table 57 Array SNMP messages (continued) SNMP message Troubleshooting advice ? > DiskArray ? > RaidSet ? DEGRADED CAUTION: Replace a failed power module as soon as possible to maximize the life expectancy of the remaining power module and to maintain redundancy. The RaidSet in this System is degraded due to one or two hard drives that are failed or missing in a RAID volume. Replace the failed or missing hard drives. Node warning SNMP messages Table 58 Node SNMP messages SNMP message Troubleshooting advice FAN on Couplet_? UUID node?_fan_#? degraded The redundant fan is not working. This notification will occur on the remaining good fan noting that redundancy is no longer working. The fans in the system need to be checked. LOGICAL_DISK on Couplet_? UUID node?_logicaldisk_#? degraded The status for the logical disk is not OK or the fault tolerance is not RAID 1. The logical disk information needs to be checked. The redundant disk system is not running as expected. NETWORK_PORT on Couplet_? UUID The link is down on the ethernet port. The cables and remaining network path node?_eth? down need to be checked in the device. POWER SUPPLY on Couplet_? UUID node?_psu_#? degraded The redundant power supply is not working. This notification will occur on the remaining good power supply noting that redundancy is no longer working. The power supplies need to be checked. TEMPERATURE_SENSOR on Couplet_? The temperature is greater than the threshhold. Airflow and surrounding UUID node?_temp_#? warn temperature need to be checked. Fans need to be checked. Network switch SNMP warning messages Table 59 Network switch warning SNMP messages SNMP message FAN on switch?_fan warn POWER_SUPPLY on switch?_powersupply_#? warn TEMPERATURE_SENSOR on switch?_temp warn Troubleshooting advice The fan is reporting a warning. The fans need to be investigated. The power supply is reporting a warning. The power supplies need to be investigated. The temperature sensor is reporting a warning. The temperature and airflow need to be investigated. Ibrix SNMP warning messages Table 60 Ibrix event messages Code CPU {0number##0}% on server {1} File system IFS1 files {90, 92, 94}% full File system IFS1 space {90, 92, 94}% full Nic {0} on host {1} configuration WARN {2} mismatch with Fusion Manager Troubleshooting advice If the % value is 90, 92, 94, this generates a warning message. If you have not already expanded the system storage to its maximum, manage backups to minimize additional storage requirements until you can expand the system. If at maximum storage, you must consider removing data from the system via replication, etc. and then deleting the cartridges/files, shares, etcetera. Otherwise, contact HP Support. Warning messages 205