HP D2D4009fc HP-StoreOnce v3.6.2 software release notes (BB852-90944, July 201 - Page 10

Update process, sftp the upgrade package to the software repository on the StoreOnce appliance

Page 10 highlights

Update process sftp the upgrade package to the software repository on the StoreOnce appliance sftp the package (D2D_Master-3.6.2-1325.1.x86_64.rpm) to the software repository.. NOTE: In the following instructions, where the term Management IP address is used, this is the IP address that you normally use to log on to the StoreOnce GUI or CLI. For StoreOnce B6200 Backup systems this is also referred to as the Management VIF. • Example 1: (using Linux) sftp Admin@ cd repository put D2D_Master-3.6.2-1325.1.x86_64.rpm exit sftp • Example 2: (using a Windows sftp client) Ensure the File Protocol is set to SFTP, not SCP. Login to the Management IP address as Admin. Copy D2D_Master-3.6.2-1325.1.x86_64.rpm to repository. Run the CLI software update commands HP StoreOnce B6200 Backup system only: IMPORTANT: If you are updating from software that is below revision 3.5.x, the 3.6.2 software update must be run by HP service engineers. To ensure smooth running of the software upgrade process, HP recommends that the HP B6200 Backup system has failover disabled prior to the upgrade. Once the software upgrade has completed successfully, failover should be manually turned back on. The status of failover can be checked using the StoreOnce CLI command: hardware show node status. The value shown in the HA (high availability) column indicates whether failover is on or off for the relevant node. Enter the following CLI commands on the active node of the HP B6200 Backup system: • system show repository which should list out the rpm file you copied over • system load package D2D_Master-3.6.2-1325.1.x86_64.rpm which, in the case of the HP B6200 Backup system, will distribute the package across all nodes it can communicate with and unpack them (into/stage/packages) • system show packages which will show you the packages staged ready for update • hardware disable failover to turn off failover (HA) hardware show node status to check that HA (failover) is reported as off for all nodes in the cluster • system update packages which will begin the process across all nodes to upgrade and reboot the nodes • hardware enable failover to re-enable failover (HA) hardware show node status to check that HA (failover) is reported as turned on for all nodes in the cluster 10 Installation instructions

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11

Update process
sftp the upgrade package to the software repository on the StoreOnce appliance
sftp
the package (
D2D_Master-3.6.2-1325.1.x86_64.rpm
) to the software repository..
NOTE:
In the following instructions, where the term Management IP address is used, this is the IP
address that you normally use to log on to the StoreOnce GUI or CLI. For StoreOnce B6200 Backup
systems this is also referred to as the Management VIF.
Example 1: (using Linux)
sftp Admin@<Management_IP Address>
cd repository
put D2D_Master-3.6.2-1325.1.x86_64.rpm
exit sftp
Example 2: (using a Windows sftp client)
Ensure the File Protocol is set to SFTP, not SCP.
Login to the Management IP address as Admin.
Copy
D2D_Master-3.6.2-1325.1.x86_64.rpm
to
repository
.
Run the CLI software update commands
HP StoreOnce B6200 Backup system only:
IMPORTANT:
If you are updating from software that is below revision 3.5.x, the 3.6.2 software
update must be run by HP service engineers.
To ensure smooth running of the software upgrade process, HP recommends that the HP B6200 Backup
system has failover disabled prior to the upgrade. Once the software upgrade has completed
successfully, failover should be manually turned back on.
The status of failover can be checked using the StoreOnce CLI command:
hardware show node
status
. The value shown in the HA (high availability) column indicates whether failover is
on
or
off
for the relevant node.
Enter the following CLI commands on the active node of the HP B6200 Backup system:
system show repository
which should list out the rpm file you copied over
system load package D2D_Master-3.6.2-1325.1.x86_64.rpm
which, in the case of
the HP B6200 Backup system, will distribute the package across all nodes it can communicate
with and unpack them (into
/stage/packages
)
system show packages
which will show you the packages staged ready for update
hardware disable failover
to turn off failover (HA)
hardware show node status
to check that HA (failover) is reported as
off
for all nodes in
the cluster
system update packages
which will begin the process across all nodes to upgrade and
reboot the nodes
hardware enable failover
to re-enable failover (HA)
hardware show node status
to check that HA (failover) is reported as turned
on
for all
nodes in the cluster
10
Installation instructions