Haier HPU-36CA03T3 Operation Manual

Haier HPU-36CA03T3 Manual

Haier HPU-36CA03T3 manual content summary:

  • Haier HPU-36CA03T3 | Operation Manual - Page 1
    CABINET TYPE AIR CONDITIONER Operation & Installation Manual HPU-32CAO3T3 HPU-36CAO3T3 No.0150505629 B • Please read this operation manual before using the air conditioner. • Please keep this manual carefully and safely.
  • Haier HPU-36CA03T3 | Operation Manual - Page 2
    ■ Content Cautions Parts Operation Operation hints Energy saving Maintenance Trouble shooting When problems occur Indoor & outdoor unit connection Tools necessary Installation procedures Others 1-2 3-5 6-11 12 13 14-15 16 17-18 19 20 21-27 28
  • Haier HPU-36CA03T3 | Operation Manual - Page 3
    conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide. The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping bag made of polyethylene and the polyethylene foam pads contain
  • Haier HPU-36CA03T3 | Operation Manual - Page 4
    • Cautions • For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications. • Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull
  • Haier HPU-36CA03T3 | Operation Manual - Page 5
    • Parts ee Z;8;88 88, 1.18:88Cr*41 ., b ZI, 4i IP T.'. , ,, 9 4 17 L' EiStWe II II II El , iii C Note:For cooling only unit,the "HEATER" light is invalid; ON/OFF: If pressing this button,the unit will enter Emergency Cooling mode ignoring the room temperature for 3 minutes. Indoor unit 3 C)
  • Haier HPU-36CA03T3 | Operation Manual - Page 6
    OFF,TIMER ON/OFF cannot be set) 8. FILTER Button Used to set up/down function of filter. 9.CODE Button Used to select Code A or B, this manual is for Code A. 10.RESET Button Press this button by using a sharp article to resume the correct operation of the remote controller in case of
  • Haier HPU-36CA03T3 | Operation Manual - Page 7
    • Parts 18.FAN Button • The distance between the remote controller and the receiver Used to select fan speed:LOW,MID,HIGH,AUTO. should be max 7m and there should be no obstacle between them. 19.TIMER OFF Display • Do not throw the remote controller, prevent it from being damaged. 20.TIMER
  • Haier HPU-36CA03T3 | Operation Manual - Page 8
    • Operation AUTO, COOL , HEAT and DRY Operation Manual Operation Remote-control unit O M,12:00 " TEMP • 3 ON 3 SWING 5 1 4 MODE SLEEP eFi5 2 LTH CD CLOCK SET CD, ) TIMER HIGH/SO O FILTER CD RESET CODE • • L5IGLHOTK
  • Haier HPU-36CA03T3 | Operation Manual - Page 9
    • Operation Manual Operation Remote-control unit dill e '12:00, ., C ) TEMP c) N 4 SWING MODE 1 3 (..•...W ). TH FRESH CLOCc( Kl)) csE) TIMER r HMSO C__D C--) CY-) FILTE O LOCK CODE 3T • • Fan Operation 1.
  • Haier HPU-36CA03T3 | Operation Manual - Page 10
    • Operation Adjusting air flow direction Swing louvers (Vertical louvers) _I_ pdl...,i II Horizontal louvers (Adjust by hand) II I II I II I Up and down II i II II • Adjust the louvers by hand to proper position. Note: Put louvers at up position in cooling and down position in heating
  • Haier HPU-36CA03T3 | Operation Manual - Page 11
    ■ Operation Sleep Function Before going to bed you can press down the SLEEP button and the air conditioner will run so as to make you sleep more comfortably. Before using this function, the clock must be set. Use of SLEEP function After the unit's start, set running mode and then press SLEEP
  • Haier HPU-36CA03T3 | Operation Manual - Page 12
    • Operation Timer ON/OFF Function Manual Operation Remote control unit r 0 A N dill co e "12100 "12100 C c ) TEMP ) ON SWING 0 0 FAN HMOEDEALFTRHES,.-H'5 nnc ' CLOCK SET TIMER 3 4 v c 3 LIGHT RESET CODE ,S • • Set clock correctly before starting
  • Haier HPU-36CA03T3 | Operation Manual - Page 13
    • Operation Timer ON-OFF Function Manual Operation Remote controller operation Set clock correctly before starting TIMER operation IL 1.Unit start After unit start, select your desired operation mode (operation mode will
  • Haier HPU-36CA03T3 | Operation Manual - Page 14
    ■ Operation hints Unit operation • Protection devices inside the unit will activate to stop unit operation, when ambient temp. is extremely low or high. • When unit is running under high humidity in cooling or dehumidifying mode, condensate might appear at outlet grill. 3-min delay protection • Unit
  • Haier HPU-36CA03T3 | Operation Manual - Page 15
    filter should be periodically cleaned If air filter is clogged: It will cause poor cooling and heating efficiency, higher power consumption and even problem may occur. In cooling operation, water will flow out. -- ="ii I O Use Timer effectively You may use Timer mode to keep a comfortable room
  • Haier HPU-36CA03T3 | Operation Manual - Page 16
    • Maintenance Disconnect power supply Don't touch it with wet Don't wash with hot water hand or solvent to clean the unit 0 IN) L 9 OFF 7,1 , - -- 6 CD Don't splash water directly on indoor unit. This could be very dangerous ____---FM 41• 0 Th Don't spray any paint or insecticide on the
  • Haier HPU-36CA03T3 | Operation Manual - Page 17
    • Maintenance Indoor and outdoor cleaning • Clean it with warm and wet cloth or with neutral detergent, then wipe it dry with clean and soft cloth. • If air conditioner is very dirty, clean it with cloth soaked in neutral detergent,then wipe off the detergent with clean water. • Don't use water
  • Haier HPU-36CA03T3 | Operation Manual - Page 18
    • Trouble shooting Followings are not problems Sound of water flowings are not problems. 11 During unit start and operation or at stop, a swishing or gurgling noise may be heard. This noise is generated by refrigerant flowing in the
  • Haier HPU-36CA03T3 | Operation Manual - Page 19
    ■ When problems occur Before asking services, please firstly check your unit according to room? 6 K If your unit still can't work properly after above mentioned checks, or following problems occur, please stop it immediately and contact your dealer. • Fuses or circuit breakers often blow out
  • Haier HPU-36CA03T3 | Operation Manual - Page 20
    • When problems occur 1. Errors display Inspection display The "Power" light flashes once The "Power" light flashes twice The "Power" light flashes three times The "Power" light flashes
  • Haier HPU-36CA03T3 | Operation Manual - Page 21
    • Indoor & outdoor unit connection O °Vet i oc OO`No°`'``' power cable length APP.= 1.5m APPS 2m pipe direction Rear Right Bottom ove n iocrn Vet lo cal Noci``' 046 Ver 75 6CN 0 46 19
  • Haier HPU-36CA03T3 | Operation Manual - Page 22
    ■ Tools necessary Tools necessary 1. Screw driver 2. Hacksaw 3. 70mm dia. hole core drill 4. Spanner (dia. 17, 27mm) 5. Spanner (14, 17, 27mm) 6. Pipe cutter 7. Flaring tool 8. Knife 9. Nipper 10. Gas leakage detector or soap water 11. Measuring tape 12. Reamer 13. Refrigerant oil Standard
  • Haier HPU-36CA03T3 | Operation Manual - Page 23
    parts like inlet and outlet grill etc. Delivery Facing up Installation of outdoor unit Selection of installation place CD Place strong enough to support the unit and will not cause vibration and noise. C=D Place where discharged wind and noise doesn't cause a nuisance to the neighbors. '0 Place
  • Haier HPU-36CA03T3 | Operation Manual - Page 24
    • Installation procedures Installation of indoor unit Selection of installation place Place where it is easy to route drainage pipe and outdoor piping. Place away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evenly to every corner of the room.
  • Haier HPU-36CA03T3 | Operation Manual - Page 25
    ■ Installation procedures Installation of fall-prevention fitting metal: Fix the fitting metal to the wall by screws so that there is no clearance between them. With the unit set up vertically, fix the fitting metal to the unit with screws while making an adjustment at the long portion of the hole
  • Haier HPU-36CA03T3 | Operation Manual - Page 26
    • Installation procedures 2. Piping connection of indoor unit Arrangement of piping and drainage pipe After opening inlet grill, you will see a control box as shown in the Fig. Remove the cover before wiring work. Cut away, with a hammer or a saw, the lid for piping according to piping direction.
  • Haier HPU-36CA03T3 | Operation Manual - Page 27
    ■ Installation procedures 3. Piping connection of outdoor unit. Connect the connecting pipe and inlet and outlet liquid pipe according to the piping method. 4.Purging method Discharge the air out of the indoor unit and the refrigerant pipe by vacuumizing (1) Fasten all the nuts of the indoor and
  • Haier HPU-36CA03T3 | Operation Manual - Page 28
    I Installation procedures Electric wiring Note: • Electric wiring must be done by qualified person. • Use copper wire only, the parameter of connecting cable is HO7RN-F 4G 2.5mm2. • The power cable should be over 5G 4.0mm2, the power cable is self-provided. • The power supply connects from the
  • Haier HPU-36CA03T3 | Operation Manual - Page 29
    of operation. (2) Test run Run the unit continuously for about 30 minutes, and check the following. • Suction pressure at check joint of service valve for gas pipe. • Discharge pressure at check joint on the compressor discharge pipe. • Temperature difference between return air and supply air for
  • Haier HPU-36CA03T3 | Operation Manual - Page 30
    mm) Liquid pipe 0 9.52mm (3/8") 1.0 - 1.8 Gas pipe 019.05mm (3/4") 1.4 - 2.2 Flaring tool 2.Installation inspection and test run: Please operate unit according to this Manual. Items to be checked during test run. Please made a 'v "in "❑" u Are there any gas leakage? u How is insulation at piping
  • Haier HPU-36CA03T3 | Operation Manual - Page 31
  • Haier HPU-36CA03T3 | Operation Manual - Page 32
    HAIER GROUP Qingdao Haier Air Conditioner Electric Co., Ltd. Address: Haier Garden, Qianwangang Road, Economic Development Zone, Qingdao, Shandong 266555, P.R.China Web Site: http://www.haier.com
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Operation
&
Installation
Manual
HPU-32CAO3T3
HPU-36CAO3T3
No.0150505629
B
Please
read
this
operation
manual
before
using
the
air
conditioner.
Please
keep
this
manual
carefully
and
safely.