Inverter units
![]() |
View all Haier AU42NALEAA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
Inverter units filter >`^^WcU[S] `_V[e[`_Wc 4 electrical expansion valve cooling 5 filter heating 3 3-way stop valve (liquid side) defrost temp. sensor condenser 4-way valve check valve 1 evaporator coil temp. sensor discharging temp. sensor suction temp. sensor muffle check valve 2 compressor air-liquid segregator 3-way stop valve (air side) 1. high pressure switch 2. low pressure switch 3. for AU182AFERA, is 2-way stop valve 4. for AU182AFERA, is main capillary 5. for AU182AFERA, is sub-capillary and single check valve for AU182AFERA, No. 1 and 2 are avaliable For AU362AHERA electrical expansion filter valve filter cooling heating way stop valve (liquid side) defrost temp. sensor Te condenser way valve evaporator outdoor ambient temp. sensor Tao check valve high pressure switch dischange temp. sensor Td suction temp. sensor Ts muffle low pressure switch oil return capillary indoor coil temp. sensor Tc indoor ambient temp. sensor Tai condenser air-inlet temp. sensor Tci compressor air-liquid separator -63- way stop valve (air side)