Gigabyte GZ-FW1CA-AJS User Manual - Page 23
cross screwdriver.
View all Gigabyte GZ-FW1CA-AJS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 23 highlights
English turn off the power and keep all the devices away from any electronic part. Note: It is strongly recommended that all coolant is drained from the liquid cooling system prior to transportation of the computer system to prevent leakage if it is dropped or damaged. Although this has already been tested before the product is dispatched from the factory, the chassis is not designed to be transported with coolant inside the liquid cooling system. e. Place the 4-way splitter valve outside of the chassis (Fig A), remove the right tube (Fig. B) and let the coolant drain into the bucket/barrel (Fig. C). Turn on power to let water in tank drain out. Warning: Use only GIGABYTE liquid coolant; any damage arising from the use of other liquid products is not covered by warranty. Leakage of liquid coolant due to improper installation may damage the system and is not covered by warranty. 4-13-8 Draining out all the coolant. a. Please make sure that all the power is turned off. b. Prepare an empty container with a cross screwdriver. c. Place the chassis on a table or higher platform and put the empty container on the floor next to the chassis. d. Using the screwdriver, remove the bottom 4-way splitter valve from the chassis. Fig. A Fig. B 23