Page 17 highlights

Installation Instructions B4 ADAPT MICROWAVE OVEN BLOWER FOR OUTSIDE BACK EXHAUST (cont.) 3 Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit. BEFORE: Fan Blade Openings Facing Up End B End A 4 Rotate the unit so that the exhaust ports face the rear of the cabinet. When you insert the blower unit, the blower wire must be as shown. Blower unit Exhaust ports 5 Place the blower unit back into the cabinet. Check that the exhaust ports face toward the rear of the cabinet. Exhaust ports WARNING: Risk of electric shock can cause injury or death. Do not pull or stretch the blower unit wiring. Make sure the wires are not pinched. NOTE: The blower unit exhaust openings should match exhaust openings on rear of microwave oven. 6 Reattach the blower plate to the cabinet so the exhaust ports and blower plate opening are aligned. Attach with 2 blower unit mounting screws and then 3 blower plate mounting screws. Blower unit Blower plate mounting screw (3 screws) Blower plate Blower unit exhaust ports Back plate Blower unit mounting screw (2 screws) 7 Attach the exhaust adapter to the rear of the oven by sliding it into the guides at the top center of the back of the oven. Adapter Back of Microwave Oven Guide Guide Locking Tabs Push in securely until it is in the lower locking tabs. Take care to ensure that the damper hinge is installed so that it is at the top and that the damper swings freely. 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

17
Installation Instructions
Attach the exhaust adapter to the rear of the
oven by sliding it into the guides at the top
center of the back of the oven.
3
ADAPT MICROWAVE OVEN
BLOWER FOR OUTSIDE BACK
EXHAUST (cont.)
B4
7
WARNING:
Risk of electric shock
can cause injury or death. Do not pull or stretch
the blower unit wiring. Make sure the wires
are not pinched.
NOTE:
The blower unit exhaust openings should
match exhaust openings on rear of microwave oven.
Push in securely until it is in the lower locking
tabs. Take care to ensure that the damper hinge
is installed so that it is at the top and that the
damper swings freely.
Guide
Guide
Adapter
Locking Tabs
Back of
Microwave Oven
BEFORE: Fan Blade
Openings Facing Up
End B
End A
Carefully pull out the blower unit. The wires
will extend far enough to allow you to adjust
the blower unit.
Rotate the unit so that the exhaust ports face
the rear of the cabinet. When you insert the blower
unit, the blower wire must be as shown.
Place the blower unit back into the cabinet.
Check that the exhaust ports face toward
the rear of the cabinet.
Exhaust
ports
Blower unit
Exhaust
ports
Back plate
Blower unit
mounting screw
(2 screws)
Blower plate
mounting screw
(3 screws)
Blower plate
Blower unit
Blower unit exhaust ports
4
5
Reattach the blower plate to the cabinet so
the exhaust ports and blower plate opening
are aligned. Attach with 2 blower unit mounting
screws and then 3 blower plate mounting screws.
6