Alternate construction, Adjusting Oven Height

Page 4 highlights

GAS WALL OVEN INSTALLATION INSTRUCTIONS 3. Alternate construction Installation Instructions for installing a 1½ cavity oven into an existing 2 cavity opening with dimen- sions 42-1/8" height by 22 ½" Width. 42 1/8" (107 cm) 22 1/2" (57.2 cm) Hole for Cord 4. Adjusting Oven Height Remove and lay aside the lower vent decorative trim that is taped to the side or to the top of the oven. The decorative trim will be fastened to the lower front of the oven after it has been installed in the cabinet. There is a 1 ½" height adjustment on models with extension panel (see Figure 5). With this adjustment and a ½" trim overhang, a unit can be installed in existing openings 37 ½" to 39" high. Wood runner Height adjuster Figure 4 Plywood filler • If width opening is too wide to secure unit to cabinet with mounting screws, add plywood filler strips. • If height opening is at 42-1/8", lower height adjuster 1" (see section 4) and secure two 2" X 4" X 22" wood runners on each side at bottom of opening (see Figure 4). • The decorative lower trim (not shown) can be installed to hide the gap under the unit. It should overlap by ¼" the front of the cabinet at bottom of cutout (see step 2 of section 5). Adjustment Holes Extension Panel Mounting Screws Figure 5 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

GAS WALL OVEN INSTALLATION INSTRUCTIONS
4
Figure 5
Extension
Panel Mounting
Screws
Adjustment
Holes
3. Alternate construction
Installation Instructions for installing a 1½ cavity
oven into an existing 2 cavity opening with dimen-
sions 42-1/8" height by 22 ½" Width.
Figure 4
(57.2 cm)
Plywood
filler
Wood
runner
42
1
/
8
"
(107 cm)
Height
adjuster
22
1
/
2
"
Hole for
Cord
If width opening is too wide to secure unit to
cabinet with mounting screws, add plywood
filler strips.
If height opening is at 42-1/8", lower height
adjuster
1" (see section 4) and secure two 2" X
4" X 22" wood runners on each side at bottom
of opening (see Figure 4).
The decorative lower trim (not shown) can be
installed to hide the gap under the unit. It should
overlap by ¼" the front of the cabinet at bottom
of cutout (see step 2 of section 5).
4. Adjusting Oven Height
Remove and lay aside the lower vent decorative
trim that is taped to the side or to the top of the
oven. The decorative trim will be fastened to the
lower front of the oven after it has been installed
in the cabinet.
There is a 1 ½" height adjustment on models
with extension panel (see Figure 5). With this
adjustment and a ½" trim overhang, a unit can be
installed in existing openings 37 ½" to 39" high.