Dell PowerStore 3000X EMC PowerStore Alerts and Events Reference Guide - Page 31
Enclosure PSU AC failure
View all Dell PowerStore 3000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Alert and Event Messages Event code Severity Alert raised Call home 0x00308504 MINOR TRUE TRUE 0x00308505 MAJOR TRUE TRUE 0x00308506 MAJOR TRUE TRUE 0x00308601 MAJOR TRUE TRUE 0x00308602 INFO FALSE FALSE 0x00308701 INFO FALSE FALSE 0x00308702 MAJOR TRUE TRUE 0x00308703 MAJOR TRUE TRUE 0x00308704 MAJOR TRUE TRUE Message Bus %(bus_num) Enclosure %(encl_num) %(identification) PHY %(phy_ports[].phy_index) health status is limited. Bus %(bus_num) Enclosure %(encl_num) %(identification) PHY %(phy_ports[].phy_index) health status is problematic. Attention is required. Bus %(bus_num) Enclosure %(encl_num) %(identification) PHY %(phy_ports[].phy_index) health status is faulty. Immediate attention is required. Expansion enclosure power supply in bus %(bus_num) enclosure %(encl_num) %(location) has no input power. Input state of the expansion enclosure power supply in bus %(bus_num) enclosure %(encl_num) %(location) has changed to %(input). The Bus %(bus_num) Enclosure %(encl_num) %(location) Expansion Enclosure PSU has %(power_failure). No AC feed to the Bus %(bus_num) Enclosure %(encl_num) %(location) Expansion Enclosure PSU was detected. The Bus %(bus_num) Enclosure %(encl_num) %(location) Expansion Enclosure PSU AC is out of range. The Bus %(bus_num) Enclosure %(encl_num) %(location) Expansion Enclosure PSU AC failure was detected. Repair flow - - System impact Overall cluster impact is limited as long as the other LCC is healthy. - - - Ensure that the power cables are plugged in to the expansion enclosure power supply correctly. No impact on cluster as long as the alternate power source for expansion enclosure is healthy. - - - - Examine the the Expansion Enclosure PSU, it could be the power-cord is loose on the Expansion Enclosure PSU. Examine the the Expansion Enclosure PSU, it could be the power-cord is loose on the Expansion Enclosure PSU. Examine the the Expansion Enclosure PSU, it could be the power-cord is loose on the Expansion Enclosure PSU. No impact on cluster as long as the alternative power source for Expansion Enclosure is healthy. No impact on cluster as long as the alternative power source for Expansion Enclosure is healthy. No impact on cluster as long as the alternative power source for Expansion Enclosure is healthy. Knowledge Base Article - https://www.dell.com/support /Article/SLN317230 https://www.dell.com/support /Article/SLN317230 https://www.dell.com/support /Article/SLN317228 - - https://www.dell.com/support /Article/SLN317228 https://www.dell.com/support /Article/SLN317228 https://www.dell.com/support /Article/SLN317228 31 Dell EMC PowerStore Events and Alerts Reference Guide