Dell PowerStore 3000X EMC PowerStore Alerts and Events Reference Guide - Page 17
Node IPMI BMC connection
View all Dell PowerStore 3000X manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
Alert and Event Messages Event code Severity Alert raised Call home 0x00305303 MAJOR TRUE TRUE 0x00305402 MAJOR TRUE TRUE 0x00305403 MAJOR TRUE TRUE 0x00305501 NONE FALSE FALSE 0x00305502 NONE FALSE FALSE 0x00305503 MAJOR TRUE TRUE 0x00305601 MINOR FALSE FALSE 0x00305602 MAJOR TRUE TRUE 0x00305603 MAJOR TRUE TRUE 0x00305604 MAJOR TRUE TRUE 0x00305605 MAJOR FALSE FALSE Message Interconnect port 1 has failed. Interconnect port 2 is degraded. Interconnect port 2 has failed. Node IPMI BMC connection state has changed from %(old_value) to %(ipmi_bmc_connected). Node IPMI BMC connection state has changed from %(old_value) to %(ipmi_bmc_connected). Node IPMI BMC connection is no longer active. Internal M.2 boot module in slot %(slot_num) has changed from %(old_value) to %(disk_failure). Internal M.2 boot module slot in %(slot_num) used as %(local_disk_purpose) is empty. InternalM.2BootModule slot %(slot_num) is expected to be empty but contains a disk. Internal M.2 boot module in slot %(slot_num) is not supported. Internal M.2 boot module in slot %(slot_num) has errors or is faulted. Repair flow Check the state of the peer Node. One or both Nodes may need to be restarted or reseated in the BaseEnclosure. Check the state of the peer Node. One or both Nodes may need to be restarted or reseated in the BaseEnclosure. Check the state of the peer Node. One or both Nodes may need to be restarted or reseated in the BaseEnclosure. - - Shut down the node, unseat it from the enclosure, and reseat it again. If the issue persists, contact your service provider. - Refer to the Installation and Service Guide to install a supported Internal M.2 boot module. - Replace it with a supported M.2 boot module. Refer to the Installation and Service Guide for more information. Replace the internal M.2 boot module. Refer to the Installation and Service Guide for more information. System impact Cluster performance may be degraded. Cluster performance may be degraded. Cluster performance may be degraded. - - Hardware monitoring may be degraded. - Performance may be degraded. - Performance may be degraded. Performance may be degraded. 17 Dell EMC PowerStore Events and Alerts Reference Guide Knowledge Base Article https://www.dell.com/support /Article/SLN317241 https://www.dell.com/support /Article/SLN317241 https://www.dell.com/support /Article/SLN317241 - - https://www.dell.com/support /Article/SLN317243 - https://www.dell.com/support /Article/SLN317231 https://www.dell.com/support /Article/SLN317231 https://www.dell.com/support /Article/SLN317231 https://www.dell.com/support /Article/SLN317231